Eolo Maior 32kW - Technical data.
ES
Nominal heat input
Minimum heat output
Nominal heat output (working)
TR
Minimum heat output (working)
Working heat performance at nominal output
Working heat performance at 30% load of nominal output
Loss of heat at shell with burner On/Off
RO
Loss of heat at stack with burner On/Off
IE
Gas nozzle diameter
Supply pressure
Max. operating pressure of heating circuit
Max. operating temperature of heating circuit
Adjustable heating temperature
Total volume of heating expansion vessel
Expansion vessel preloading
Generator water content
Available head with a flow rate of 1000 l/h
Working heat output for the production of hot water
D.h.w. adjustable temperature
D.h.w. flow limiting device at 2 bar
D.h.w. circuit min. (dynamic) pressure
D.h.w. circuit maximum operating pressure
Minimum domestic hot water run off
Specific flow rate (∆T 30°C)
Specific flow rate in continuous duty (∆T 30°C)
Full boiler weight
Empty boiler weight
Electrical connection
Rated power input
Installed electrical power
Power absorbed by the circulator
Power absorbed by the fan
Appliance electrical system cutout
Rated power fumes mass flow
Minimum power fumes mass flow
CO
at Q. Nom./Min.
2
CO at 0% of O
at Q. Nom./Min.
2
NO
at 0% of O
at Q. Nom./Min.
X
2
Fumes temperature at nominal output
Fumes temperature at minimum output
NO
class
X
NO
weighted
X
CO weighted
Type of appliance
Category
- Fume temperature values refer to the inlet air temperature of 15°C.
- The data relevant to domestic hot water performance refer to a dynamic
inlet pressure of 2 bar and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet considering that to obtain the data
declared, mixing with cold water is necessary.
122
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
G20
mm
1.35
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
W
W
-
G20
kg/h
66
kg/h
67
%
7,5 / 2,5
ppm
110 / 70
ppm
160 / 100
°C
122
°C
116
-
mg/kWh
mg/kWh
C12 /C32 / C42 / C52 / C82 / B22 / B32
II2H3+
- The max. sound level emitted during boiler operation is < 55dBA. The
sound level value is referred to semianechoic chamber tests with boiler
operating at max. heat output, with extension of fume exhaust system
according to product standards.
34,4 (29579)
12,5 (10750)
32,00 (27520)
10,5 (9030)
93,0
91,5
0,50 / 0,46
6,50 / 0,01
G30
G31
0.79
0.79
29 (296)
37 (377)
3
90
35 - 85
7,4
1,0
3,5
39,42 (4,0)
32,00 (27520)
30 - 60
9,0
0,3
10
1,5
14,8
15,3
49,5
46,0
230/50
0,96
170
98
60
IPX4D
G30
G31
68
70
70
72
8,4 / 2,8
8,1 / 2,7
95 / 77
60 / 80
211 / 111
210 / 100
121
118
115
113
2
190
56