and the adapter Ø 60/100 in Ø 80/125 (see fig.). This configuration
corresponds to a resistance factor of 100. In this case special extensions
ES
must be requested.
TR
RO
IE
N.B.: When installing the ducts, a section clamp with pin must be
installed every 3 metres.
• External grill. N.B.: For safety purposes, do not even temporarily obstruct
the boiler intake/exhaust terminal.
Vertical kit with aluminium tile Ø 80/125. Kit assembly: install the
concentric flange (2) on the boiler central hole inserting the seal (1) and
tighten using the screws supplied with the kit. Fit the male end (smooth)
of the adapter (3) in the female end of the concentric flange (2). Installing
the fake aluminium tile. Replace the tiles with the aluminium sheet (5),
shaping it so that rainwater runs off. Position the fixed half-shell (7) on the
aluminium tile and insert the intake/exhaust pipe (6). Fit the male end (6)
(smooth) of the Ø 80/125 concentric terminal up to the stop on the female
end (with lip seals) of the adapter (3), making sure that the ring (4) is fitted;
this will ensure hold and joining of the elements making up the kit
5
4
3
2
1
• Coupling extension pipes and concentric elbows. To install possible
coupling extensions on other fume exhaust elements, proceed as follows:
fit the male end (smooth) of the concentric pipe or concentric elbow up
to the stop on the female end (with lip seals) of the previously installed
element; this will ensure correct hold and joining of the elements.
Important: if the exhaust terminal and/or extension concentric pipe needs
shortening, consider that the internal duct must always protrude by 5 mm
with respect to the external duct.
This specific terminal enables fume exhaust and combustion air intake in
a vertical direction.
N.B.: The vertical kit Ø 80/125 with aluminium tile enables installation on
terraces and roofs with maximum slope of 45% (24°) and the height between
the terminal cap and half-shell (374 mm) must always be respected.
The vertical kit in this configuration can be extended to a max. vertical
straight length of 12200 mm, including the terminal (see fig. below). This
configuration corresponds to a resistance factor of 100. In this case specific
extensions must be requested.
Terminal Ø 60/100 can also be used for vertical exhaust, together with
concentric flange code no. 3.011141 (sold separately). The height between
102
the terminal cap and half-shell (374 mm) must always be respected (see
fig. below).
C32
8
The kit comprises:
1 - Seal (1)
1 - Female concentric flange (2)
7
1 - Adapter Ø 60/100
for Ø 80/125 (3)
1 - Ring (4)
1 - Aluminium tile (5)
1 - Concentric intake/exhaust
pipe Ø 80/125 (6)
1 - Fixed half-shell (7)
6
1 - Movable half-shell (8)
The vertical kit in this configuration can be extended to a max. vertical
straight length of 4700 mm, including the terminal (see fig. below).
C12
Separator kit Ø 80/80. The separator kit Ø 80/80, enables division of the ex-
haust flues and air intake pipes according to the diagram shown in the figure.
Fumes are expelled from duct (A). Combustion air drawn through duct (B).
Intake duct (B) can be installed either on the right or left side of the central
exhaust duct (A). Both ducts can be routed in any direction.
9
A
7
4
1
The kit comprises:
1 - Exhaust seal (1)
1 - Flange seal (2)
1 - Female intake flange (3)
1 - Female exhaust flange (4)
• Fitting the Ø 80/80 separator kit. Install the flange (4) on the central
hole of the boiler, fitting seal (1), and tighten with the flat-tipped hex
screws in the kit. Remove the flat flange on the lateral hole (depending
on installation requirements) and replace with flange (3) inserting seal
(2) already fitted on the boiler and tighten using the self-tapping screws
supplied. Fit the male end (smooth) of the bends (5) in the female end
of the flanges (3 and 4). Fit the male end (smooth) of the intake terminal
(6) up to the stop on the female end of the bend (5), making sure that
the relevant internal and external rings are fitted. Join the exhaust pipe
(9) with the male section (smooth) in the female section of the bend
(5) to the end stop, ensuring that the internal washer is fitted; this will
ensure the sealing efficiency of the kit components.
5
6
7
5
B
3
2
2 - 90° bend Ø 80 (5)
1 - Intake terminal Ø 80 (6)
2 - White internal rings (7)
1 - Grey external ring (8)
1 - Exhaust pipe Ø 80 (9)
C32
C82
8