SETTING VIA A WEB BROWSER
Batch Items
Count Quantity Setting
[Functional overview]
The number of screws to fasten is set.
The number of fastened screws
determined as OK is counted, and
when it reaches the set quantity, you
are notified of that with a buzzer and
the lighting detection lamp.
P. 26
• The count quantity appears on the tool
display in operation mode.
• When it reaches the set quantity, the
count on the display will be reset.
In the screen for the tool number, select the "Batch" tab and make settings.
Select a parameter from the "Parameter" pull-down menu and set "Batch size"
(quantity to fasten, up to 99). Click [Set] to set the values for "Repeat mode (Basic
mode)".
* One type (one parameter only) per tool can be registered.
* To switch the tool, select the desired one from the tool list.
* Up to 5 batches can be registered.
* Refer to "SETTING FASTENING PARAMETERS OF TOOLS" and "SETTING THE
FASTENING CONTROL MODE" in the Operating Instructions of the controller
(EYARW1).
For parameters, refer to "Parameter Items".
Tool list
[Default value]
1
[Setting value]
1 to 99
40
EN
(cont.)
When it is set to "3"
A short
A short
A long
beep
beep
beep
Solid green
Solid green
Solid blue
1st screw
2nd screw
3rd screw
Fastening OK
Fastening OK
Fastening OK
P. 33
Device settings Items
Brake
[Functional overview]
You can enable or disable braking when rotation stops before clutch activation.
[Default value]
ON
[Setting value]
ON
Braking disabled (Rotation stops immediately when you release the
trigger switch.)
OFF
Braking disabled (Rotation stops slowly when you release the trigger
switch.)
Ignore judgement time
[Functional overview]
You can exclude unexpected rotations
that are unrelated to work, such as brief
idling and screw hole alignment in push
start mode, from detection.
Set the duration of rotations to exclude
from detection.
[Default value]
0.00 s
[Setting value]
0.00* s to 9.99 s
Entering the value with (*) will disable the function.
When it is set to "0.30"
Ignore
Judgement
Rotations within
0.30 s
Rotations within 0.30 s are excluded from
fastening detection.