TROUBLE SHOOTING CHECK LIST
Before asking for a technical assistance service, please follow this list to try to solve most common problems:
PROBLEM
The machine does not work
Working temperature
not sufficient
Egg-turner device not
working properly
Forced ventilation not sufficient
Thermometer mercury
column interrupted
Whichever reparation attempt non included on above mentioned form is severably forbidden.
Contact always the manufacturer or the authorized technical assistance in your country.
Fiem s.n.c. di Tina Luccini & C. - Tel: 0039 (0)31 976672 - Fax: 0039 (0)31 899163
WIRING DIAGRAM
Correct working of the fan should be checked visually, faulty operation of the fan could compromise incubation results.
2
the fan will be checked by sight, its bad working could compromise incubation results.
16
CAUSE
Lack of power
Plug disconnected
Safety fuse burnt
Any of the above points
Heating element
not correctly working
Thermostat not calibrated
Thermostat faulty or not working
Plastic lid not inserted
Cold room under 17/18°C
Egg-turner motor broken
Egg-turner motor disconnected
Fan not working
2
Accidental drops or jarring
of the thermometer
SOLUTION
Check the plug
Put the plug into the socket
Replace the fuse 2AT (5x20)
Contact the assistance service
Contact the manufacturer
See instruction for calibration
Contact the manufacturer
Insert the plastic lid
Place the incubator into a warmer room
Contact the manufacturer
See egg-turner motor
connecting paragraph
Contact the manufacturer
Try to put the thermometer at low
temperature (in a freezer) for few
minutes, and then allow to return
to room temperature. Otherwise
replace the thermometer
The working of