Consumer Safety Information
Safety symbols and signal words
This is the safety alert symbol. This symbol
alerts you to potential hazards that can kill or
hurt you and others.
indicates a hazardous situation
which, if not avoided, will result in death or
serious injury.
indicates a hazardous situation
which, if not avoided, could result in death or
serious injury.
indicates a hazardous situation
which, if not avoided, could result in minor or
moderate injury.
is used to address practices not
related to physical injury.
Other important information or tips
Safety behavior and practices
Ensuring a safe operating environment
• Danger of suffocation! To ensure dis-
sipation of exhaust gases, operate the
Combi furnace outdoors only.
– Never use in enclosed spaces or tents or
breathe in the exhaust gases.
– If installing an airtight awning, make
sure that the exhaust system terminates
outdoors.
– If the RV is parked in an enclosed space:
– Block the flow of fuel to the Combi
furnace.
– Deactivate the time switch.
– Switch off the Combi furnace at the con-
trol panel.
• Use the Combi furnace only with a func-
tional LP gas and carbon monoxide detector
installed in the RV. For installation, operation
and function test follow the manufacturer's
guidelines.
• Keep the area around the Combi furnace free
from combustible materials, gasoline, and
other flammable vapors or liquids such as
pressurized dispensers or wax candles.
6
• Keep the area in front of the warm air outlets
(Fig. 1 – H) free of combustible or heat-sen-
sitive materials. Do not put any material into
the warm air outlets.
• In order to avoid overheating of the Combi
furnace, keep the air inlets of the Combi
furnace (Fig. 2 – 11), the air openings to the
area in which the Combi furnace is installed
(Fig. 1 – D) and the spacing around the
Combi furnace free of obstruction.
• To ensure clean combustion, keep the wall
cowl free of obstruction. Do not lean any ob-
jects against the wall cowl (Fig. 1 – F).
CARBON-MONOXIDE POISONING HAZARD!
Failure to follow instructions could result
in severe personal injury or death due to
carbon-monoxide poisoning, if combustion
products enter the RV.
Check that all openings in the outside wall
around the vent (and air intake) pipe(s) are
sealed to prevent combustion products en-
tering the RV.
Check that furnace vent (and air intake)
terminal(s) are not obstructed in any way
during all seasons.
• Danger of hot surfaces. The temperature of
the exhaust gases can reach 320 °F (160 °C).
Do not touch the area around the wall cowl
and do not lean any objects against the wall
cowl or the RV.
Responsibilities of the operator
• The operator is responsible for the water filled
into the Combi water container and its quality.
• The operator is responsible for protecting the
Combi furnace against freezing.
Safe operation
• Use with LP gas (propane) only. Butane or
any mixtures containing more than 10 % of
butane must not be used.
– LPG tanks must be filled by a qualified gas
supplier only.
• Danger of damage to the gas system! For
the operation of gas pressure regulation sys-
tems, gas-burning devices or gas systems
only gas cylinders that supply gas in the
gaseous phase may be used. Gas cylinders