Kenmore 79033233400 Instrucciones De Instalación página 5

Idiomas disponibles

Idiomas disponibles

Typical Under Counter
Installation
of an Electric Built-in
Oven with a Cooktop
Mounted
Above
All mounting hardware
must be used to secure
the builtqn oven to tile
cabinets. Refer to the
builtqn
oven installa-
tion instructions.
Junction box must
be located approx.
3" to the left of
the builtqn oven
cutout,
208/240 Volt grounded junction
box for built-in
This cooktop may
be installed over
certain builtqn elee
tric oven models.
Side filler panels are necessary to
isolate the unit from adjoining
cabinets. Panel height should allow
for installation of approved cooktop
models. See "Typical Gas Cooktop
Installation Over an Electric Builtqn
Oven Installed Under the Counter"
on previous page.
32" Min.**
(81.3 cm)
36"
(91.4 cm)
Use 3/4" (1.9 cm) plywood, installed
on two runners, flush with toe plate.
Must be capable of supporting 150 Ibs.
Cut an opening in wood base minimum 9"
(22.9 cm) x 9" (22.9 cm), 2" (5.1 cm) from
left side filler panel, to route armoured
(.able to junction box.
4 1/2" (11.4 cm)
Max.*
*
If no cooktop is installed directly
over the oven unit, S" (12.7 cm)
maximum is allowed.
** 32" (81.3 cm) min. from top of
cabinet to top of runners must be
maintained.
CUTOUT
DIMENSIONS
(inches)
OVEN SIZE
E
F
G
Min
Max,
Min
Max,
30"
27¼"
28s/_"
281/2"
29"
23Y2"
(76,2cm)
(69,2cm)
-
(727cm)
(72,4cm)
-
(737cm)
(59,7cm)
27"
27¼"
28s/_"
24V8"
25¼"
23Y2"
(68,6crn)
(69,2crn)
-
(727cm)
(63,1cm)
(641cm)
(59,7cm)