11
Technical data
11.1
Technical specifications
The "Technical Data" section contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Sensing range
Min. sensing range
Sensing range max.
Recommended sensing range for the best performance
Reference object
Distance value
Distance value measuring range
Distance value-resolution
Distance value reproducibility
Distance value – accuracy
Distance value output
Refresh rate of distance value
Emitted beam
Light sender
Type of light
Light spot size / distance
Communication interface
Table 13: Communication interface
IO-Link
IO-Link
Data transmission rate
Electrical data
Supply voltage U
B
Ripple
Current consumption
Protection class
1)
Limit values
Reverse polarity protected U
B
Residual ripple max. 5 V
ss
8028212/2023/10/20 | SICK
Subject to change without notice
connections
OPERATING INSTRUCTIONS
www.sick.com
under the part number of the sensor.
WTM4S
4 mm (MultiMode 1, 3, 4, 5)
0 mm (MultiMode 2)
4 mm (MultiMode 1 + 6)
250 mm (MultiMode 1, 3, 4, 5)
250 mm (MultiMode 2)
500 mm (MultiMode 1 + 6)
40 mm ... 170 mm (MultiMode 1, 3, 4, 5)
40 mm ... 140 mm (MultiMode 2)
50 mm ... 200 mm (MultiMode 1 + 6)
Object with 90% remission factor (complies
with standard white according to DIN 5033)
MultiMode M
10 mm ... 250 mm
0.1 mm
via IO-Link
20 ms
WTM4S
PinPoint-LED
Sichtbares Rotlicht
4.0 mm (150 mm)
WTM4S
1.1
COM2
WTM4S
DC 10 ... 30 V
1)
≤ 5 Vpp
25 mA
III
O P E R A T I N G I N S T R U C T I O N S | WTM4S
en
61