dPart number
Filter
Colour
number
type
code
401201
P R SL
White
401209
AP R SL
White
Brown
401215
ABP R SL
Brown
Gray
White
401216
ABEP R SL
Brown
Gray
Yellow
White
401217
ABEK P
Brown
R SL
Gray
Yellow
Green
White
401218
ABEKHgP
Brown
R SL
Gray
Yellow
Green
Red
White
Facepiece
1. Connect the bayonet connector of the breathing hose to the blower unit.
2. Connect the other end of the breathing hose to the facepiece.
WARNING
Penetration of ambient air!
Make sure that all components are securely and firmly connected to each other before use.
3.2.4
Switching on the device
1. Switch on the blower unit by pushing one of the buttons on the control panel for
approx. 3 seconds.
• When switching on the blower unit the first time the unit will guide you through the
required steps for correct functioning of the unit. See annex I for an explanation of
14
RSG Safety BV | Powered Air Purifying Respirator T-Air® | June 2021
n
Main application
Solid and liquid particles (Aerosols)
Organic gases and fumes with boiling point >65°C
Solid and liquid particles (Aerosols)
Organic gases and fumes with boiling point >65°C
Inorganic gases and fumes like Chlorine, H2S, HCN
Solid and liquid particles (Aerosols)
Organic gases and fumes with boiling point >65°C
Inorganic gases and fumes like Chlorine, H2S, HCN
Sulphur dioxide (SO2) and acid gases and vapours
Solid and liquid particles (Aerosols)
Organic gases and fumes with boiling point >65°C
Inorganic gases and fumes like Chlorine, H2S, HCN,
Sulphur dioxide (SO2) and acid gases and vapours
Ammonia and organic amines
Solid and liquid particles (Aerosols)
Organic gases and fumes with boiling point >65°C
Inorganic gases and fumes like Chlorine, H2S, HCN,
Sulphur dioxide (SO2) and acid gases and vapours
Ammonia and organic amines
Mercury
Solid and liquid particles (Aerosols
these steps.
2. After switching on, the device performs a self-test.
3. Correct malfunction if the device fails to work properly or warning devices are
triggered (see section 4 Troubleshooting).
4. Don the facepiece (see Instructions for Use of the corresponding facepiece).
5. Adjust the flow rate using the + and - buttons as desired.
3.3
During use
WARNING
Health hazard!
Leave the danger zone immediately in case of:
• Decreasing or interrupted air supply (e.g. after blower unit failure)
• In the hood/helmet/protective visor facepiece type, carbon dioxide can quickly build
up or lack of oxygen may occur. Noxious ambient air may also penetrate the hood.
• Odour or taste developing in the facepiece (filter gas filter components of the
combination filter are exhausted.
• Drowsiness, dizziness, or other complaints
• Damage to the equipment
• Other indicated alarms (see section 4 Troubleshooting)
Breathing hoses or other components involve the risk of getting caught. This may damage
the device and interrupt the air supply!
Handle the device with care.
Breathing in during heavy work while wearing the facepiece may result in negative
pressure and the penetration of unfiltered ambient air!
Increase the flow rate to prevent this from happening.
3.3.1
Adjusting the flow rate
If necessary (e.g. during increased physical exertion), the flow rate can be adjusted during
operation using the + and - buttons.
3.3.2
Warnings and alarms
If a warning appears, leave the working area promptly in view of the potentially
hazardous situation.
Lower the flow rate to increase the period of service if a warning appears. (Only possible
if the lowest level has not already been chosen.) By lowering the flow rate you can e.g.
extend the battery runtime.
If an alarm is triggered, leave the working area immediately without any delay.
Check the function of the device after a warning or alarm has been triggered (see section 4 ).
3.4
After use
GB
GB