Error code
LED BLINKS
11
(4,1)□□□□ □
65
(4,2)□□□□ □□
(4,3)□□□□ □□□
4,13
(4,4)□□□□ □□□□
60
69
(4,5)□□□□ □□□□□
12
(5,1)□□□□□ □
(5,2)□□□□□ □□
130
i
NOTE
*LED ON: When there is no failure, the LED indicator is on.
*LED OFF: The controller is not powered on.
REV. 09/2022
Explanation
Current Sensor
MOS
EEPROM fault
Motor Open
TEMP Sensor
EMCY STOP
SRO
D
4
Possible cause
The current circuit is abnormal
MOS device damage
EEPROM failure or fault.
The motor did not connect
The temperature sensor is
disconnected or short-circuited.
The emergency stop button being
pressed was detected.
SRO failure.
Before power-on, the lift button
be pressed. After the fault is
show, walking is not affected, but
the lifting is prohibited.
Release the lift button and power
on the device again.