RS Pro RS-5500 Manual De Instrucciones página 3

Idiomas disponibles
  • ES

Idiomas disponibles

Digital Insulation Tester/English
When servicing, use only specified replacement parts.
CE
Comply with EN-61010-1
CAT III 1000V
Measurement
Application
Category
Measurements on circuits not directly connected to mains.
Examples include: Measurements on battery powered equipment and specially
protected (internal) mains-derived circuits.
Measurements on circuits directly connected to the low voltage installation.
Examples include: Household appliances, portable tools and similar equipment.
Measurements performed in the building installation.
Examples include measurements on distribution boards, junction boxes,
socket-outlets and wiring and cables in the fixed installation.
Measurements performed at the source of the low-voltage installation.
Examples include measurements on primary overcurrent protection devices
and electricity Instruments
1.SPECIFICATIONS
1-1 General Information
Environment conditions:
① Installation CAT III 1000V
② Pollution Degree 2
③ Altitude up to 2000 meters
④ Indoor use only
⑤ Relatively humidity 80% max.
⑥ Operation Ambient 0~40ºC
Display:
Large LCD with dual display
Measurement Range:
200 , 200k , 200M /250V, 200M /500V,
2000M /1000V, 750V/ACV, 1000V/DCV.
Sampling Rate:
2.5 times per second.
Zero Adjustment:
Automatic adjustment.
2
Over Range Indicator:
Number 1 of highest digit is displayed.
Low Battery Indication:
The
is displayed when the battery Voltage
drop below the operating voltage.
Operating Temperature:
0ºC to 40ºC (32ºF to 104ºF) and Humidity below
80% RH
Storage Temperature:
-10ºC to 60ºC (14ºF to 140ºF) and Humidity below
70% RH
Power source:
DC9V (6x1.5V Size "AA" battery or Equivalent)
Dimensions:
200(L) x 92(W) x 50(H) mm
Weight:
Approx 700g include battery
Supplied Accessories:
Test leads, 6pcs battery, Carrying case, manual.
1-2 Electrical Specifications
Accuracies are specified in the way:
±(...% of reading +...digits) at 23ºC±5ºC,below 80% RH.
OHMS
Range
Resolution Accuracy Max. open
200Ω
0.1Ω
+(1%+2)
200kΩ
0.1kΩ
Continuity Beeper
Range
Resolution Operation
Resistance
•)))
0.1
Ω
Resistance≤40
Short circuit current
≤200mA
Digital Insulation Tester/English
Overload
Circuit
Protection
Voltage
4.5V
250Vrms
3.0V
Max.open
Overload
Circuit
Protection
Voltage
Ω
4.5V
250Vrms
3
loading