Care and maintenance
Warning!
Before doing any work on
the machine, pull the plug
out of the socket.
Use original replacement
parts only.
Contaminated 昀椀lters must be
treated as special waste.
Dispose of replaced equip-
ment parts, 昀椀lters or old
devices in accordance with
the rules and regulations
applicable in your country.
Notice
Different 昀氀uxes and 昀氀ux
constituents and the amount
of and size of dust particles
in the extracted air will signi昀椀
cantly effect the 昀椀lters wor-
king life. A gas 昀椀lter (without
particle 昀椀lter) must be used
for the extraction of adhesive
fumes.
Error messages and error clearance
Message/symptom
Extraction power missing
Loud extraction noises
Zero Smog is not running
Filter display is not
working
Particle 昀椀lter depleted too
quickly
Unable to detect USB
medium
Reset unit
24
To ensure that the 昀椀ltration system functions properly, the 昀椀lter must
be replaced as follows
at least once a year or
when indicated or
if the maximum allowable workplace concentration is exceeded or
as per maintenance schedule
The degree of clogging of the 昀椀lter is determined by differential pres-
sure measurement. The 昀椀lter display indicates the current 昀椀lter status
Red = 昀椀lter full
Yellow = 昀椀lter status > 80%
Green = 昀椀lter status < 80%.
When the 昀椀lter is used up, an audible signal sounds
once an hour
every half hour after 36 hours
every 10 min after 54 hours
continuously after 72 hours.
The particle 昀椀lter and the gas 昀椀lter are co-ordinated in such a way
that they can be replaced together as a compact 昀椀lter unit. The com-
pact 昀椀lter must be changed once a year in order to ensure it is fully
functional. The 昀椀ne dust 昀椀lter (昀椀lter mat) is the preliminary stage of
the compact 昀椀lter and therefore must be replaced more frequently.It
is suf昀椀cient to replace the pre昀椀lter mat if the red LED does not come
on after restarting the unit.
Possible cause
Pipe system leaking
Filter is dirty
Turbine speed too low
Air speed through extractionarm
is too high speed
Thermally switched off
Minimum pressure hose was not
replaced after the 昀椀lter change
Pre-昀椀lter has not been used
USB medium inserted too long
Wrong USB medium > 100 mA
Remedial measures
Reseal the pipe system
change the 昀椀lter
Increase the speed setting
Reduce the air speed (reduce air
quanitity)
Leave the Zero Smog to cool
down Switch on again afterap-
prox. 3 hours
Reconnect the hose to the 昀椀lter
Use a pre-昀椀lter Fit an F7 昀椀lter
Use a preliminary seperator if the
proportion of solid matter is high.
Do not leave USB medium
inserted for longer than 2
minutes. Remove USB medium
and switch unit off and on again
Remove USB medium!