MENU → SETTINGS → Installer level → Installation configuration
→ Heat generator 1
→ Status:
→ Current flow temperature: °C
→ Circuit 1
→ Status:
→ Target flow temperature: °C
→ OT switch-off
threshold: °C
→ Heat curve:
→ Min. target flow
temperature:°C
→ Max. target flow
temperature:°C
→ Set-back mode:
The behaviour can be adjusted separately for each heating circuit.
→ Room temp. mod.:
0020323630_00 Operating and installation instructions
Enter the upper limit for the outdoor temperature. If the outdoor tem-
perature rises above the set value, the system control deactivates
heating mode.
The heat curve (→ section "Product description") is the dependence
of the flow temperature on the outdoor temperature for the desired
temperature (target room temperature).
Enter the lower limit for the target flow temperature. The system
control compares the set value with the calculated target flow tem-
perature, and regulates to the larger of these values.
Enter the upper limit for the target flow temperature. The system
control compares the set value with the calculated target flow tem-
perature, and regulates to the smaller of these values.
→ Eco
The heating function is switched off and the frost
protection function is activated.
At outdoor temperatures that are below 4 °C for
longer than four hours, the system control switches
the heat generator on and regulates to the Set-
back temperature: °C. At an outdoor temperature
above 4 °C, the system control switches the heat
generator off. The monitoring of the outdoor tem-
perature remains active.
Heating circuit behaviour outside of the time peri-
ods. Prerequisite:
– Time-contr. is activated in the Heating →
Mode: function.
– Active or Inactive is activated in the Room
temp. mod.: function.
If Expanded is activated in the Room temp.
mod.:, the system control regulates to the target
room temperature 5 °C independently of the
outdoor temperature.
→ Normal
The heating function is switched on. The system
control regulates to the Set-back temperature: °C.
Prerequisite: Time-contr. is activated in the Heat-
ing → Mode: function.
→ Inactive
→ Active
Adjusting the flow temperature based on the cur-
rent room temperature.
13