MENU → SETTINGS
→ Display bright-
ness:
→ Dimmed displ.
brightness:
→ Daylight saving
time:
The change takes place:
– On the last weekend in March at 02:00 (daylight saving time)
– On the last weekend in October at 03:00 (standard time)
→ Offset
→ Room temperat-
ure: K
→ Outdoor temper-
ature: K
→ Factory settings
2.10.4
Installation configuration menu item
MENU → SETTINGS → Installer level → Installation configuration
→ Installation
→ Water pressure: bar
→ eBUS components
→ Adaptive heat
curve:
→ Control:
→ OT constant heat-
ing:
Desired preheating
temp.:
12
Brightness during active use.
Brightness in standby.
→ Automatic
→ Manual
Comparison of the temperature difference between the measured
value in the system control and the value for a reference thermometer
in the living room.
Comparison of the temperature difference between the measured
value in the outdoor temperature sensor and the value for a reference
thermometer in the living room.
The system control resets all of the settings to the factory settings and
calls up the installation assistant.
Only the competent person can call up the installation assistant.
List of eBUS components and their software versions
Automatic fine adjustment of the heat curve. Prerequisite:
– The suitable heat curve for the building is set in the Heat curve:
function.
– The correct zone is assigned to the system control or the remote
control in the Zone assignment: function.
– Expanded is selected in the Room temp. mod.: function.
R.temp.contr
It is controlled via the room temperature.
Weath.-comp. It is controlled via the outdoor temperature as soon
as an outdoor temperature sensor is connected.
If the outdoor temperature falls below the set temperature value,
the Heat curve: is used to regulate to a room temperature of 20 °C
outside of the time periods.
OT ≤ set temperature value: No night set-back or total shut-down
Factory setting: Off
This is where you can select the desired pre-heating time temper-
ature in order to activate the heating before the heating programme
first starts. The aim is to reach the room temperature at the desired
time. The system automatically calculates the required prerun time
(max. 4 hrs) based on prior experience, the current room temperat-
ure and the time remaining until the programme changes.
Factory setting: Off
Operating and installation instructions 0020323630_00