TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slow-down
T3
distance [%]
Motor 1 closing
T4
delay time [s]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Storage
1
Radio
2
Fast closing
3
Pre-alarm
4
3-step logic
Opening
5
impulse block
6
Reversing Stroke
7
SWC pressure
Motor 2 opening
8
delay time
30
- ZARA BT A80
INSTALLATION MANUAL
+
+
max.
min.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
10
100
WARNING: It affects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
NOTE: When this parameter is edited, a new Autoset cycle must be run to confirm it.
Set slow-down speed as a percentage of total travel. This distance is travelled at low speed.
5
50
NOTE: When this parameter is edited, a new Autoset cycle must be run to confirm it.
Motor 1 closing delay time with respect to motor 2.
NOTE: set 0 for single motor operations (leaf 1).
0
25
NOTE: if the time is set to maximum, before starting, engine 1 waits for the complete shut down of
engine 2.
Cross out
Default
Description
setting used
Disables the saving of remote controls via radio and automatic insertion of clones. The remote con-
OFF
trols are stored only using the dedicated Radio menu, or automatically with replay transmitters.
IMPORTANT: Disables automatic insertion of new remote controls, clones
Enables the saving of remote controls via radio:
1- Press the hidden button and the normal button in sequence (T1-T2-T3-T4) of a remote control
already saved in standard mode through the radio menu.
OFF
2- Within 10 seconds, press the hidden button and the normal button (T1-T2-T3-T4) of a remote
ON
control to be saved.
The receiver quits the programming mode after 10 seconds; within this time further new remote
controls can be inserted.
This mode doesn't require access to the control panel.
IMPORTANT: Enables automatic insertion of new remote controls, clones and replay transmitters.
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
ON
OFF
The flashing starts at the same time that the motor(s) start(s) up
OFF
ON
Flashing starts approx. 3 seconds before the motor(s) start(s) up
OFF
Switches to 4-step logic.
OFF
ON
Switches to 3-step logic; during closing, start
reverses movement.
OFF
The start impulse has an effect during opening.
OFF
ON
The start impulse has no effect during opening.
Logic not active
OFF
Before making a manoeuvre, both opening and closing, the gate pushes for around 2 seconds in
OFF
ON
the opposite direction. This allows the electric lock to release more easily.
IMPORTANT - Do not use this function without adequate mechanical end stops.
The movement is stopped solely by the intervention of the closure limit switch; in this case, it is
OFF
necessary to precisely regulate the operation of the closure limit switch.
To be used with mechanical closure stop.
This function activates pressure of the leaf on the mechanical stop, without this
OFF
being considered an obstacle by the amperostop sensor.
ON
The rod therefore continues its stroke for a few seconds after interception of the closure limit
switch or up to the mechanical stop. In this manner, by slightly advancing the intervention of
the closure limit switches, the leaf will come into perfect contact with the end stops.
OFF
Motor 2 opening delay time compared to motor 1 = 1 second.
OFF
ON
Motor 2 opening delay time compared to motor 1 = 3 seconds.
Description
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens