BFT ZARA BT A80 Instrucciones De Instalación página 28

Ocultar thumbs Ver también para ZARA BT A80:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
Terminal
60
62
70
71
72
Y
#
(*) Other voltages available on request
(*) If "D" type devices are installed (as defined by EN12453), connect in unverified mode, foresee mandatory maintenance at least every six months.
Only with expansion board
Terminal
22
23
28
29
63
64
65
76
77
78
79
80
5) LOCAL COMMANDS Fig. B
Pressing the S3 key commands one START. By pressing the key again while the
automated device is moving a STOP is commanded.
6) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
6.1) CONNECTION OF SAFETY DEVICES FIG. D
7) MEMORIZING TRANSMITTERS FIG. E
8) AUTOSET ADJUSTMENT FIG.F
Enables Motor Torque to be set automatically.
If the power is suddenly disconnected and then restored the automation performs
the operations at autoset speed till the travel limits are identified.
WARNING! The autoset operation must be performed only once you have che-
cked that the leaf is moving accurately (opening/closing) and that the mechanical
stops and end stops are positioned correctly.
You must run an autoset cycle whenever the position of the end stops, the motor
force (T2) or the slow-down distance (T3) are changed. .
WARNING! While the autoset function is running, the obstacle detection function
is not active. Consequently, the installer must monitor the automated device's
movements and keep people and property out of range of the automated device.
WARNING: the torque values set by the autoset function refer to the motor force
set during the autoset cycle. If motor force is edited, an autoset opening and
closing cycle will need to be performed again.
WARNING: check that the force of impact measured at the points provided for
by standard EN 12445 is lower than the value laid down by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury to
people and animals.
SOLENOID LOCK
WARNING: In the case of leaves longer than 3m, it is essential to install
a solenoid lock.
28
- ZARA BT A80
INSTALLATION MANUAL
Definition
Common
START and OPEN inputs common
Configurable control input 1 (N.O.) - Default START
IC1
START/OPEN/CLOSE/PED
Refer to table "D" I/O Configuration DIP switch 1 and DIP switch 2
Common
STOP, PHOT and BAR inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
Configurable safety input 1 (N.O.) - Default PHOT
SAFE 1
PHOT / PHOT TEST / PHOT OP TEST / PHOT CL TEST / BAR / BAR OP TEST / BAR CL TEST / BAR 8K2
Refer to table "D" I/O Configuration DIP switch 3, DIP switch 4 and DIP switch 5
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal
bodies close to the antenna can interfere with radio reception. If the transmitter's range is limited, move
SHIELD
the antenna to a more suitable position.
Definition
AUX 10
Area light control
Free contact
(N.O.)
(230V >5A°)
DIP switch 8 I/O config OFF=12V latch electric lock output= (max.300W)
Output activated with impulse on each opening.
LOCK 12/24V=
Dip8 I/O config ON=EBP drop lock output active throughout the entire manoeuvre.
Max 1A° for 1 s , 0.2A for the rest of the manoeuvre.
Common
Common inputs IC3, IC4
IC10
Control 3 input (N.O.) PED
IC11
Control 4 input (N.O.) CLOSE
Common
Common inputs SAFE3 - SAFE4 - SAFE5 - SAFE6
SAFE 10
Safety input 3 (N.C.) BAR safety edge
SAFE 11
Safety input 4 (N.C.) Phot photocell
SAFE 12
Safety input 5 (N.C.) BAR OP Safety edge with inversion active only on opening
SAFE 13
Safety input 6 (N.C.) PHOT OP Photocell active only on opening
Description
Description
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add second radio channel
S2
see table "D" I/IO CONFIG"
S2
Confirms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
Pressed BRIEFLY, it gives the START command.
S3
HELD DOWN (>5 sec.), it activates the AUTOSET function.
S1+S2
During LOW ENERGY exits from LOW-ENERGY