Insert dip stick
Remove the plug (16) from the
1.
crankcase.
16
17
2.
Substitute the plug with the dip stick
supplied (17).
The plug prevents oil from leaking from
the crankcase during shipping. Keep
plug for future use.
4.2
Mains connection
B
Danger! High voltage
Operate machine in dry envi-
ronment only.
Operate machine only on a power
source complying with the following
requirements:
− outlets properly installed, earthed
and tested;
− fuse protection in accordance
with the Technical Specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the machine
is switched OFF before plugging in.
Protect
power
cable
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
Do not stop the compressor by
unplugging, but switch OFF using the
switch.
Unplug after use.
4.3
Generating compressed
air
Start compressor (18) and wait until
1.
the max. tank pressure is reached
(compressor shuts off).
The tank pressure is indicated by
the tank pressure gauge (19).
19
Set pressure regulator (20) to
2.
required working pressure. The cur-
rent working pressure is indicated
by the regulated pressure gauge
(21).
A
Caution!
The regulated pressure may
not be set higher than the max. wor-
king pressure of the connected air
tools!
3.
Connect air hose to compressed air
outlet (22).
4.
Connect air tool.
You are now ready to work with the
air tool.
5.
Switch the compressor OFF, if you
do not continue working immediately
afterwards. Unplug after switching
OFF.
5. Care and Maintenance
Danger!
A
from
heat,
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the compressor has
come to a complete stop.
− Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts
machine.
Repair and maintenance work other
than described in this section must
only be carried out by qualified speci-
alists.
5.1
Periodic maintenance
Prior to each use
•
Check
replace if necessary.
18
20
21
22
remain
on
or
in
the
air
hoses
for
damage,
ENGLISH
•
Check all screwed connections for
tightness, tighten if necessary.
•
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 operating hours
•
Check air intake filter (23), clean if
necessary.
23
•
Check oil level, top up if necessary
(24).
24
•
Drain condensate (25).
25
Every 250 operating hours
•
Replace air filter element.
Every 500 operating hours
•
Drain oil and fill with fresh oil.
Every 1000 operating hours
•
Have unit serviced by an authorized
service station. This will extent the
compressor's service life considera-
bly.
5.2
Machine storage
1.
Switch unit OFF and unplug.
2.
Release pressure from tank and all
connected air tools.
9