If your outlet
looks llke this:
(_
hen choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 3-wire power supply cord, at least 4 ft
3-wire
receptacle
(10-30R)
(1.22 m) long, must have three lO-gauge
copper
wires and match a 3-wire
receptacle
of NEMA
Type 10-30R.
If connecting
by direct
wire:
Power supply cable must match power supply (4-wire or 3-wire)
and
be:
[]
Flexible armored cable or nonmetallic sheathed copper cable
(with
ground
wire),
protected
with flexible metallic conduit.
All current-carrying
wires must be insulated.
[]
10-gauge
solid copper
wire.
(Do
not
use aluminum.)
[]
At least 5 ft (1.52 m) long.
GROUNDING iNSTRUCTIONS
[]
For a grounded, cord-connected
washer/dryer:
This washer/dryer
must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This washer/dryer uses a cord having an
equipment-grounding
conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
[]
For a permanently connected washer/dryer:
This washer/dryer
must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on
the washer/dryer.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the washer/dryer
is properly grounded. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE
THESE
INSTRUCTIONS
ELECTRICAL REQUIREMENTS
- 240 VOLT MODELS
(CANADA)
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical
shock.
It is your responsibility
[]
To contact a qualified electrical installer.
[]
To be sure
that
the
electrical
connection
is adequate
and
in
conformance with the Canadian Electrical Code, C22.1 - latest
edition and all local codes A copy of above codes standard
may
be obtained
from:
Canadian
Standards
Association,
178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
[]
To supply the required 4 wire, single-phase_ 240 volt_ 60 Hz.,
AC-only electrical supply on a separate 30-amp circuit_ fused
on both sides of the line. A time-delay fuse or circuit breaker is
recommended,
Connect
to an individual branch circuit.
[]
[]
[]
This dryer
is equipped
with a CSA
International
Certified
Power Cord
intended
to be plugged
into a
standard
14-30R wall receptacle.
The cord
is 5 ft. (1.52 m) long.
Be sure wall
receptacle
is within
reach
of laundry
center's
location.
4-wire
receptacle
(14-30R)
If using a replacement
power
supply cord,
it is recommended
that you use Power Supply
Cord Replacement
Part Number
9831317.
For further
information,
please
reference
service
numbers
located
on the back cover.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord=connected washer/dryer:
This washer/dryer
must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electric shock by providing a path of least resistance for
electric current. This washer/dryer
is equipped with a cord
having an equipment-grounding
conductor and a grounding
plug. The plug must be plugged into an appropriate outlet
that is properly installed and grounded in accordance with
all local codes and ordinances.
WARNING"
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the
washer/dryer is properly grounded. Do not modify the plug
provided with the washer/dryer:
if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.
SAVE THESE