Assembly
(Con't)
For 10 inch diameter
wheels, feed
the shoulder bolt through
the top
hole on the tank axle iron and
tightly
secure with the Iocknut.
Repeat on the opposite side.
• _
Grip
Figure 3- Optlomll
Assembly
OPTIONAL
VERTICAL
SIORAGE
GROUND
IRON
1. Push plastic plug into end of one inch
tube.
2. Assemble the grip onto the tube as
described
in the handle assembly.
3. Assemble the tube to the tank as
shown in figure
8. Fasten the tube
with 5/16 inch locking bolts. Tighten
securely with 5/16 inch locking nuts.
4. Assemble rubber foot with 5/16 inch
washer. Insect threaded
pest of
rubber feet into holes at top of tube.
Tighten
securely with 5/16 inch
locking nuts.
NOTE: See Parts List for exploded
assembly.
Installation
LOCATION
When assembled,
the tank must sit
level or slope slightly towards
the drain
cock to allow the tank to drain
properly,
It is extremely
important
to install the
compressor in a dean. well ventilated area
where the surrounding air temperature
will not be morethan
t00*F.
A minimum
clearance
of 18 inches
between
the compressor and a wall is
required because
objects could obstruct
air flow.
rR =7_=lt_[d = 1;
DO not/ocat_
the
near _
pa/nt spray, sandbtaurt
areas or any oth_
source of
€onMm/flab_n,
This debris wilt damage
I_be motor.
GILECTRIC_L INST,4U.ILATION
IAWARNINGI
A,I-_V_R.,_
ateOWcal
€oemKl_s
lhoutd
bt _
by a
qu_//f_d
e/ec/rida_
Insf_//ation
must be
/n axx_am:e
with/oca/€odes
and
_l_#
mc_-blcat _o_es.
GROUNDING
INSTRUCTIONS
1. This product is for use on a nominal
120 volt circuit and has a grounding
plug that looks llke the plug illustrated
in Fig. 4. Make sure the product is
connected to an Outlet having the
same COnfiguration as the plug. ThiS
product must be grounded, in the
event
of an electrical short circuit,
grounding
reduces risk of electrical
shod( by providing
an escape wire for
electric current. This product is
equipped
with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.
md_ kl i _*m_db/e n_k of
w/_ _p_oduct_
2. it repalror reple©ementof cord or ping
is necessary, do not connectgrounding
wire to either fiat blade terminal. The
wire with insulationhavingan external
surfacethat isgreen (with or without
yellow stripes)isthe grounding wire.
WL6500
Series
_WARNINGI
_.v,,o_._
IF_n
(or g_Nm and
yetlow) wlre to a _ve tmmlnaL
3. Che_k with a qualified electrician
or
sen*iceman if grounding
instructions
are not completely understood, or if in
doubt as to whether
product is
properly
grounded. Do not mndify
plug provided; if it will not fit outlet.
have proper outlet installed by a
qualified electrician.
WIRING
1. Local electrka_ wiring codes differ from
area to area. Source wiring, plug and
p_otect_r must be rated for at least the
amperage and voltage indicated on
motor nameplate, and meet all electrical
codes for this minimum.
2. Use a slow blow fuse or a circuit
breaker,
IACAUTION]
d._
._.re
damage wf# result fn_-n/nade<F_ fe
whig.
et_
NOTE: 120 volt, 15 amp units can be
operated on a 120 volt circuit under the
following conditions:
a. No other electrical appliances or lights
are connected to the same branch
drcuit.
b. Voltage
supply is normal.
r. Circuit is equipped
with a 15 amp
circuit breaker
or a 15 am p slow blow
fuse.
3. ff tbese €onditions cannot be met or if
nuisance tripping of current
protection device occurs, it may be
necessar/to
operate compressor
from
a 120volt.
20 amp circuit.