Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These
compressors power spray guns, impact
wrenches and other tools. These units
operate without oil.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
DANGER
!
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
WARNING
!
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
CAUTION
!
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
© 2003 Campbell Hausfeld/Scott Fetzer
All manuals and user guides at all-guides.com
Oilless Air
Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Model
Information
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
A listing of service center locations is
enclosed. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
Do not operate
WARNING
!
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety
Information
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
For parts, product & service information
visit www.chpower.com
WL6500 Series
Need
Assistance?
Call Us First!
1-800-543-8622
DANGER
!
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
MANUAL
thoroughly familiar
with the controls and
the proper use of the equipment.
2. Follow all local electrical and safety
codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).
IN610200AV 9/03
Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld WL6500 Serie

  • Página 17 ADVERTENCIA Guarde estos números para indica que anularán y la compañia Campbell Hausfeld hay una situación que PODRIA ocasionarle referencia en el futuro. no asumirá NINGUNA responsabilidad por la muerte o heridas de gravedad.
  • Página 18: Informaciones Generales De Seguridad

    All manuals and user guides at all-guides.com Compresores Sin Aceite Troubleshooting Chart (Continued) Informaciones Nunca Ensamblaje ADVERTENCIA debe Generales de Seguridad Symptom Possible Cause(s) ENSAMBLAJE DEL MANGO desconectar o tratar de ajustar las válvulas El mango del compresor tiene una (Continuacíon) de seguridad.
  • Página 19 All manuals and user guides at all-guides.com Serie WL6500 Instalación cable de desvío a la corriente eléctrica. Ensamblaje Este producto tiene un cordón con un UBICACION (Continuacíon) alambre y terminal de conexión a tierra. Debe conectarlo a un Una vez que lo ensamble, el tanque debe debe estar en el lado opuesto a la pieza tomacorrientes que esté...
  • Página 20: Funcionamiento

    All manuals and user guides at all-guides.com Compresores Sin Aceite Maintenance 2. Place unit in the adecuados y cumplen los requisitos automáticamente cuando alcance la 1. Coloque el presostato en OFF y as shown in Figu mínimos especificados en este presión mínima fijada en la fábrica.
  • Página 21: Mantenimiento

    All manuals and user guides at all-guides.com Serie WL6500 Mantenimiento Debe Funcionamiento ADVERTENCIA reempla- (Continuacíon) MANOMETRO DEL TANQUE zar la válvula de seguridad si no la puede Mide la presión del tanque activar o si hay fugas de aire una vez que PERILLA DEL REGULADOR para verificar que el sistema haya soltado el anillo.
  • Página 22: Guía De Diagnóstico De Averías

    All manuals and user guides at all-guides.com Compresores Sin Aceite Guía de Diagnóstico de Averías Assembly (Con't) WARNING For 10 inch diameter wheels, feed connections should Problema Posible(s) Causa(s) Acción a tomar the shoulder bolt through the top qualified electrician El compressor no 1.
  • Página 23: Recomendaciones De Herramientas Para Este Compresor De Aire

    All manuals and user guides at all-guides.com Serie WL6500 Guía de Diagnóstico de Averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar Exceseso de humedad 1. Exceso de agua en el tanque 1. Drene el tanque en el aire expulsado 2. Humedad alta 2.
  • Página 24: Safety Guidelines

    Retain instructions for future reference. Tres años; Serie Modelo Maxus - Cinco años. 2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3. QUIEN RECIBE ESTA GARANTIA (EL COMPRADOR): El comprador original (que no sea un revendedor) del producto Campbell Hausfeld.

Este manual también es adecuado para:

Ironforce wl6500 serie

Tabla de contenido