Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
BUILT TO LAST
Description
Oilless compressors are designed for
do-it-yourselfers with a variety of home
and automotive jobs. These compres-
sors will power spray guns, impact
wrenches and other tools. These units
operate without oil.
Safety Guidelines
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
NOTICE
!
important
information, that if not followed, MAY
cause damage to equipment.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service. In case of
© 1997 Campbell Hausfeld
Oilless
Stationary
TM
Compressors
DO NOT RETURN THE
PRODUCT TO THE
STOP!
RETAILER!
Record the Model No., Serial No. and
date of purchase located on the base
below the pump in the space below.
Model No. ____________________
Serial No. ____________________
Date of purchase _________________
Retain these numbers for future
reference.
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance or call the nearest Campbell
Hausfeld Authorized Service Center.
A listing of service center locations is
enclosed. Have the serial number,
model number and parts list (with
missing parts circled before calling).
Do not operate
unit if damaged
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
WL6000 Series
Call Us First!
1-800-543-8622
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be used "as
is" to supply breathing quality air. For
any application of air for human
consumption, you must fit the air
compressor/pump with suitable in-line
safety and alarm equipment. This
additional equipment is necessary to
properly filter and purify the air to
meet minimal specifications for Grade
D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 - 1966,
OSHA 29 CFR 1910. 134, and/or
Canadian Standards Associations
(CSA).
DISCLAIMER OF WARRANTIES
IN THE EVENT THE COMPRESSOR IS
USED FOR THE PURPOSE OF
BREATHING AIR APPLICATION AND
PROPER IN-LINE SAFETY AND ALARM
EQUIPMENT IS NOT SIMULTANEOUSLY
USED, EXISTING WARRANTIES ARE
VOID, AND CAMPBELL HAUSFELD
DISCLAIMS ANY LIABILITY
WHATSOEVER FOR ANY LOSS,
PERSONAL INJURY OR DAMAGE.
General Safety
Information
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure
pumping system, the following safety
precautions must be observed at all
times:
1. Read all manuals
included with this
product carefully. Be
thoroughly familiar
with the controls and
the proper use of the equipment.
IN203402AV 11/97
Need
Assistance?
MANUAL
Tabla de contenido
loading

Resumen de contenidos para Campbell Hausfeld WL6000 Serie

  • Página 1 WILL result in death or serious EQUIPMENT IS NOT SIMULTANEOUSLY injury. USED, EXISTING WARRANTIES ARE Date of purchase _________________ VOID, AND CAMPBELL HAUSFELD Warning indicates DISCLAIMS ANY LIABILITY Retain these numbers for future a potentially WHATSOEVER FOR ANY LOSS, hazardous situation which, if not reference.
  • Página 2 Operating Instructions Oilless Stationary Compressors engine/motor and check General Safety 16.Do not direct paint or other sprayed immediately for the cause. Vibration material at the compressor. Locate Information (Continued) is generally a warning of trouble. compressor as far away from the spraying area as possible to 11.To reduce fire hazard, keep 2.
  • Página 3 Operating Instructions WL6000 Series Never connect Installation (Continued) green (or green STOP! and yellow) wire to a live terminal. Never use an extension Never use the 3. Check with a qualified electrician or cord with this product. wood shipping Use additional air hose serviceman if grounding instructions skids for mounting the compressor.
  • Página 4 Operating Instructions Oilless Stationary Compressors Operation (Continued) Discharge Tube Check Valve (Opposite Side) (Opposite Side) power cord from the electrical outlet or when changing air tools. Regulator - The regulator controls the amount of air pressure released at the Pressure hose outlet.
  • Página 5 Operating Instructions WL6000 Series The compressor should be checked If thermal overload protector shuts Operation (Continued) often for any visible problems and the motor OFF frequently look for the following maintenance procedures following causes released, or valve is stuck and cannot should be performed each time the 1.
  • Página 6: Troubleshooting Chart

    Operating Instructions Oilless Stationary Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action 1. Plugged in? Check fuse/breaker or motor overload. Compressor will not run 1. No electrical power 2. Replace blown fuse 2. Blown fuse 3. Breaker open 3. Reset, determine cause of problem 4.
  • Página 7 Operating Instructions WL6000 Series Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Tank pressure drops 1. Loose connections (fittings, tubing, 1. Check all connections with soap and water solution and tighten when compressor shuts etc.) 2. Loose drain cock 2. Tighten 3.
  • Página 8 8. RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY: A. Deliver or ship the Campbell Hausfeld product or component to the nearest Campbell Hausfeld Authorized Service Center. Freight costs, if any, must be borne by the purchaser.
  • Página 9 UTILISÉ SIMULTANÉMENT, LES potentielle qui PEUT résulter en perte GARANTIES EN EXISTANCE SERONT Garder ces numéros pour référence. de vie ou blessures graves. ANNULÉES, ET CAMPBELL HAUSFELD NIE TOUTE RESPONSABILITÉ POUR N’IMPORTE Attention ATTENTION demander conseil ou appeler un Centre QUELLE PERTE, BLESSURE OU DOMMAGE.
  • Página 10 Instructions d’Utilisation Compresseur Sans Huile 11. Pour réduire le risque d’incendie, garder 17. Suivre les instructions du fabriquant Généralités Sur La l’extérieur du moteur libre d’huile, de pendant la pulvérisation ou le Sécurité (Suite) solvant ou de graisse excessive. nettoyage avec des solvants ou produits chimiques toxiques.
  • Página 11 Instructions d’Utilisation Series WL6000 INSTRUCTIONS DE MISE À LA TERRE est mis à la terre correctement, vérifier Installation (Suite) avec un électricien ou une personne 1. Ce produit est conçu pour l’utilisation qualifiée. Ne pas modifier la fiche d’un circuit de 120 volts et a une Ne pas AVERTISSEMENT fournie;...
  • Página 12 Instructions d’Utilisation Compresseur Sans Huile Fonctionnement (Suite) Tuyau de décharge Clapet (Sens opposé) (Sens opposé) débranchement du cordon d’alimentation de la prise de courant ou pendant le Régulateur changement d’outils pneumatiques. Manostat Régulateur - Le régulateur sert à régler Branchement la pression d’air à...
  • Página 13 Instructions d’Utilisation Series WL6000 1. Tirer sur l’anneau de la soupape de Fonctionnement (Suite) ATTENTION sûreté et la laisser revenir à sa moteur position normale. doit se refroidir avant que le bague est relâchée ou si la bague est démarrage soit possible. Le moteur se S’il y a AVERTISSEMENT prise, la soupape DOIT être remplacée.
  • Página 14: Guide De Dépannage

    Instructions d’Utilisation Compresseur Sans Huile Guide De Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne 1. Manque de puissance électrique 1. Modèle branché? Vérifier le fusible/disjoncteur ou fonctionne pas surcharge du moteur. 2. Fusible sauté 2. Remplacer le fusible sauté 3.
  • Página 15: Guide De Dépannage (Suite)

    Instructions d’Utilisation Series WL6000 Guide De Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesures Correctives Perte de pression dans 1. Raccordements dégagés (raccords, 1. Vérifier tous les raccordements avec de l’eau le réservoir à air quand tuyaux, etc.) savonneuse et les serrer le compresseur se coupe 2.
  • Página 16: Garantie Limitée

    8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Livraison ou expédition du produit ou de la pièce Campbell Hausfeld au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Página 17: Descripción

    Guarde estos números para indica GARANTÍAS SE ANULARÁN Y LA que hay una situación que PODRIA referencia en el futuro. COMPAÑIA CAMPBELL HAUSFELD NO ocasionarle la muerte o heridas de ASUMIRÁ NINGUNA RESPONSABILIDAD gravedad. Servicio Autorizado De Campbell POR PÉRDIDAS, HERIDAS PERSONALES Hausfeld más cercano.
  • Página 18: Instalación

    Instrucciones para la operacion Compresores Sin Aceite válvulas de seguridad. Igualmente, Informaciones Instalación debe evitar que se le acumule pintura u Generales de Seguridad otros materiales. UBICACION (Continuación) PELIGRO Es sumamente importante que instale el compresor en un lugar limpio y bien ¡Nunca trate de reparar o 5.
  • Página 19: Funcionamiento

    Instrucciones para la operacion Serie WL6000 ALAMBRADO Instalación tierra similar al de la Figura 2. Cerciórese de conectarlo a un 1. Los códigos eléctricos varían de un área (Continuación) tomacorrientes cuya configuración sea a otra. Sin embargo, el alambrado, similar a la del enchufe. Este producto enchufe y protectores se deben Nunca se debe conectar a tierra.
  • Página 20 Instrucciones para la operacion Compresores Sin Aceite Funcionamiento Tubería de descarge Válvula de chequeo (lado opuesto) (Continuación) (lado opuesto) Válvula de chequeo - Esta válvula solo permite que el aire entre al tanque y evita que éste se regrese al Regulador Presostato cabezal.
  • Página 21: Mantenimiento

    Instrucciones para la operacion Serie WL6000 libere toda la presión del sistema antes PROTECTOR TERMICO Funcionamiento de tratar de instalar, darle servicio, Este PRECAUCION (Continuación) cambiar de lugar o darle cualquier tipo compre- de mantenimiento. sor está equipado con un protector activar con el anillo, DEBERA Este compresor se debe chequear con automático contra sobrecarga térmica...
  • Página 22: Guía De Diagnóstico De Averías

    Instrucciones para la operacion Compresores Sin Aceite Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción a tomar El compressor no funciona 1. No hay energía eléctrica 1. ¿Está conectado? Chequée el fusible/cortacircuito o protector de sobrecarga del motor 2. Fusible quemado 2.
  • Página 23 Instrucciones para la operacion Serie WL6000 Guía de diagnóstico de averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar La presión del tanque baja 1. Conexiones flojas (conexiones, tuberías, 1. Chequée todas las conexiones con agua enjabonada y apriételas cuando el compresor se etc.) apaga 2.
  • Página 24: Garantía Limitada

    8. RESPONSABILIDADES DEL COMPRADOR BAJO ESTA GARANTIA: A. Entregar o enviar el producto o componente Campbell Hausfeld al Centro de Servicio autorizado Campbell Hausfeld más cercano. Los gastos de flete, de haberlos, deben ser pagados por el comprador.

Tabla de contenido