Sime 25 BF TS2 Manual De Instrucciones página 69

Ocultar thumbs Ver también para 25 BF TS2:
Idiomas disponibles

Idiomas disponibles

TYPE OF COAXIAL DISCHARGE Ø 60/100
KEY
1
Coaxial duct kit code 8084811 + connection code 8093101
2 a Extension L. 1000 code 8096103
2 b Extension L. 500 code 8096102
3
Vertical extension L. 200 code 8086908
4
Additional 90° elbow code 8095801
6
Articulated tile code 8091300
7
Terminal roof exit L. 1284 code 8091200
8
Vertical condensation recovery L. 200 code 8092803
IMPORTANT
- The insertion of every extra 90° elbow reduces the availa-
ble section by 1.00 meters.
- The insertion of every extra 45° elbow reduces the availa-
ble section by 0.50 meters.
- The insertion of the condensation recovery (8) is recom-
mended for vertical sections of more than 2.5 meters and
limits the max. length to 4 meters.
In dischar ge types
C12-C42, use diaph-
ragms ø 86 only when
the length of the
coaxial duct is less
than 1 meter.
TYPE OF COAXIAL DISCHARGE Ø 80/125
KEY
1
Coaxial duct kit code 8084830 + connection code 8093101
2
Extension L. 1000 code 8096130
3
Vertical extension L. 200 ø 60/100 code 8086908
4 a Additional 90° elbow code 8095820
4 b Additional 45° elbow code 8095920
5
Adapter for ø 80/125 code 8093120
6
Articulated tile code 8091300
7
Terminal roof exit L. 1284 code 8091200
8
Vertical condensation recovery L. 200 code 8092803
IMPORTANT:
– Each additional 90° elbow installed reduces the available length by
1.00 metres.
– Each additional 45° elbow installed reduces the available length by
0.50 metres.
– The insertion of the condensation collector (8) is obligatory in C32
discharge type.
– The insertion of the condensation collector (8) is obligatory in C42
discharge type when the stretch "y" is longer than 2.5 metres.
4
y
C42
x + y = max 3,5 m "25"
x + y = max 3,6 m
x + y = max 3,0 m "30-35"
In discharge type C32, according to the length of the duct and without extra curves,
use ø 86 and ø 87.5 diaphragms as follows:
Installations with vertical extension
L. 200 code 8086908
Diaphragm
Diaphragm
standard ø 86
optional ø 87,5
(code 6028623) (code 6028624)
L min = 1,3 m
L min = 2,5 m
L max = 2,5 m
L max = 4 m
4
5
y
C42
x + y = min. 3,6 m/max 6 m "25"
x + y = min. 3,6 m/max 7 m "30"
7
x
6
2
2
3
3
C32
max 3,5 m "25"
max 3,6 m
max 3,0 m "30-35"
C12
Installations with condensation
recovery code 8092803
Without
Diaphragm
diaphragm
optional ø 87,5
(code 6028624)
L min = 4 m
L max = 2,5 m
L max = 5 m
x
2
3 8
5
C32
min. 3,6 m - max 6 m "25"/7 m "30"
1
1
2
C12
8
1
Without
diaphragm
L min = 2,5 m
L max = 4 m
Fig. 9
7
6
2
8
1
Fig. 9/a
67
loading

Este manual también es adecuado para:

30 bf ts2