82
AVENTICS | DDL | R499050020–BDL–001–AD
Assembly
1
2
5
4
Output module
O0...O7
4
3
1
1
2
5
4
Table 8:
Pin
1
2
3
3
4
5
Housing
1. Wire the outputs according to Tab. 9 (DO8_M8) or Tab. 10
(DO8_M12).
2. Connect the electrical inputs/outputs to the I/O modules
with M8 or M12 coupling plugs (accessories).
3. To ensure the IP65 protection class, close unused sockets
with M8 or M12 protective caps (accessories).
Table 9:
Pin
1
4
3
Housing
Table 10:
Pin
1
2
3
3
4
5
Housing
Input assignment for 8x input module, 8DI_M12, M12x1
socket, A-coded
Signal
SENSOR+
I1, I3, I5 or I7
SENSOR–
I0, I2, I4 or I6
NC
Output assignment for 8x output module, 8DO_M8,
M8x1 socket
Signal
Free
Ox
GND
Output assignment for 8x output module, 8DO_M12,
M12x1 socket, A-coded
Signal
NC
O1, O3, O5 or O7
GND
O0, O2, O4 or O6
NC
Assignment
24 V sensor supply
Sensor signal
GND reference potential
Sensor signal
Not connected
Connected to shield potential
Assignment
Not connected
Output signal
(nominal voltage 24 V)
GND actuator reference
Connected to shield potential
Assignment
Not connected
Output signal
Reference potential
Output signal
Not connected
Connected to shield potential