Operation of manual pumping of fuel.
In the turned off state, press the setting buttons "up" / "down" simultaneously or press the manual pumping
button
only for 2 seconds. Manual pumping will be performed and will stop when the button is released.
Use with caution.
Plateau mode.
Press the settings button
mode. The sign
will appear on the display. To exit plateau mode, press and hold the same two buttons
simultaneously. This mode is recommended to be used above an altitude of 2000 m above sea level. In this
mode, the fuel-to-air ratio is reduced to accommodate hypoxia at high altitudes.
Setting the time switch operation time.
Press and hold the "OK" button and the "down" button simultaneously for two seconds. It will enter the time
configuration interface. The display will show the hour value and the icon
displayed. If the display shows OFF, it means that the shutdown time has been set:
1. Press the setting button "Up" / "Down" to adjust the time value, time range: 1-24 hours.
2. Briefly press the ON / OFF button
3. Briefly press the settings button
4. Briefly press the "OK" button to save the settings and exit the interface.
5. Press the settings button
6. Start/stop timer functions. Press and hold the settings button
button "up" to start the timer function. The timer will start in the timer for turning on in the off
state and the timer off in the on state. "ON" or "OFF" will be flashing, "ON" means temporary launch
and "OFF" means temporary shutdown. Briefly press the settings button "
remaining time.
Pairing the remote control
In the off state, simultaneously press and hold the ON/OFF button
seconds to enter the remote control pairing mode as shown below:
1. Press the "Up"/"Down" setting buttons to set the third digit of the remote control coding, a number
from 1 to 5 for the five remote controls respectively.
2. After selecting the desired remote control number, press any button on the remote control to pair
it with the device and exit the pairing mode.
Error codes
As shown below, the corresponding error symbol and the corresponding device component symbol flash.
The displayed data represents the error code. Their meaning can be found in the error table. Flashing
EN
at the same time as the "OK" button for 2 seconds to switch to the "plateau"
to switch between the numbers to be set.
to switch between startup and shutdown times.
for 2 seconds to exit the interface without saving the settings.
will flash, the ON sign will be
at the same time as the setting
" to display the
and the set "down" button for 2