Kenmore 24 Manual Del Propietário página 30

Idiomas disponibles

Idiomas disponibles

Performance
Data Sheet
Kenmore
Filtration
System
WR97X
10006
Cartridge
Health
Claim Performance
Certified
by NSFIANSI*
(100% safety factors built in for unmeter'ed
usage)
Standard
No. 42: Aesthetic
Effects
Paxameter
Chlorine
T&O
Particulate**
USEPA
MCL
Influent
Challenge
2,06 ppm
3,100,064
Effluent
%Reducdon
Average
Maximum
Average
Minimum
0,14 ppm
0.3 ppm
93
85
519
2425
99.98
99_92
Parameter
Turbidity
Cysts
Standard
No. 53: Health
Effects
USEPA
Influent
Effluent
% Reduction
MCL
Challenge
Average
Maximum
Average
Minimum
1 NTU***
2325 NTU
010 NTU
0,17 NTU
996
99,3
99,95%
Reduction
494,169
92
179
99,98
9996
Lead at pH 6_5
15 ppb
157 ppb
3 ppb
3 ppb
>98
>98
Lead at pH 8.5
15 ppb
162 ppb
3 ppb
3 ppb
>98
>98
* Tested using a flow rate of 0,5 gpm; pressure of 60 prig; pH of 7,5 -+05; remp, of 20 ° ± 2-5°C
** Measurement in Particlesfml
*** NTU=Nephelometric
Turbidity
units
Operating
Specifications
° Capacity: certified for up to 200 gallons (757 l)
° Temperature:
33°-100 ° F (0.6°-38 ° C)
° Pressure requirement:
40-120
psi (2_8-8.2 bar), non-shock
• Flow rate: 0.5 gpm (1.9 lpm)
General
_nstallationlOperationlHaintenance
Requirements
° Flush new cartridge at full flow for 60 seconds to purge out trapped air.
° Replace cartridge when flow becomes too slow; at least eve W six months.
Special
Notices
o Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
, This drinldng water' system must be maintained
according to manufacturer's
instructions,
including replacement
of' filter cartridges.
° Do not use where the water is microbiologically
unsafe, m with waters of unlmown quality without adequate
disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that
may contain filtetable cysts.
° The
contaminants
or other substances
removed
or reduced by this water treatment
system are
not necessarily
in your wateL
° Check for compliance with the state and local laws and regtdations.
NSF International
Standards
Standard
No. 42:Aesthetic
Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction, Class I
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard
No. 53: Health
Effects
Chemica! Reduction Unit
Lead Reduction
Mechanical Filtration Unit
Cyst Reduction
Turbidity Reduction
The Kenmore Filtration System and WR97X10006
Cartridge
have been
tested and Certified by NSF only for the functions listed immediately
above.
Manufactured
by: Sears, Roebuck and Co., Hoffman Estates, IL 60179
Tested& Certified
to ANSI]NSF
Standards42& 53
3O
loading

Este manual también es adecuado para:

2830