Aritech DI601 Manual De Instrucciones página 7

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
5.
The programming LED flashes twice showing that the new
value has been stored. The detector returns to normal
operation.
Resetting options
To reset the detector to the default settings:
1.
Remove the power from the detector.
2.
Press and hold the programming button (see Figure 16,
item 2).
3.
Apply the power to the detector.
4.
After the programming LED flashes, release the
programming button.
You can reset the detector either before installation, with a PP3
battery, or by applying 12 V to the unit on site.
Walk test
In walk test mode, the blue detection LED option is set to ON.
The detection LED lights each time DI601 detects your
presence.
To enter the walk test mode, press the programming button
once. The unit can then be aligned. The detection LED lights
on DI601 every time detection takes place.
The test mode ends automatically five minutes after last
detection. Alternatively, press the program button three times,
or remove and then reapply power to cancel the walk test
mode.
Note:
When you conduct a walk test, make sure that the front
cover is in place. Do not conduct walk tests with the cover
removed.
The range of the detector increases without the protective front
cover. Therefore the front cover must be fitted to establish the
correct beam pattern. Use Table 3 on page 6 to adjust the
range as necessary. Pan and tilt the lens module over the field
of view to obtain the correct coverage area.
Accessories
Carrier Fire & Security can provide a handheld walk tester
DI601-WT to aid installations.
Specifications
Detection range
Programmable: 10 m / 30 ft., 20 m / 66 ft., or
30 m / 98 ft.
10 to 70° detection angle, 30 x 24 m /
Coverage
98 x 79 ft. coverage max.
180° pan, 90° tilt
Adjustment
Fresnel lens
28 zones for each detection element, which
can be masked with the curtain sliders
Double silicon shielded quad element
Customized optics
eliminates 50,000 lux of white light
LEDs
Red: Programming LED
Blue: Detector alarm
Infrared: Walk tester communication
P/N 1069153 (ML) • REV G • ISS 14DEC20
Outputs
Silent, solid state, magnetically immune.
Volt free relay, signal contact 24 VAC/DC at
NO
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
NC
Volt free relay, signal contact 24 VAC/DC at
50 mA with an integral 25 Ω series resistor.
Alarm time 5 seconds.
Power input
9 to 15 V
Current
7 mA nominal (at 12 V )
17 mA max.
Pulse count
1 or 2
Temperature
Analogue (thermistor) and digital sensitivity
compensation
adjustment
Control
Digital microprocessor with nonvolatile
memory
Output test mode with LED indication.
Walk test
Option to disable LEDs.
−30 to +65°C / −22 to 149°F
Operating temperature
Housing
High impact ABS plastic with HDPE cover,
UV stabilized
Dimensions, W x H x D
125 x 175 x 130 mm / 4.92 x 6.89 x 5.12 in.
Weight
306 g net, 532 g gross / 10.79 oz net,
18.77 oz gross
Mounting height
Variable up to 6 m / 20 ft.
Optimum height 3 m / 10 ft. for full range
Utilising all three outputs (including tamper)
Cable < 200 m / 656 ft.
— eight-core 7/0.2 mm² / 24 AWG
Cable < 500 m / 1640 ft. Utilising all three outputs (including tamper)
— eight-core 16/0.2 mm² / 20 AWG
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL FIRE
AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
EN 50130,
EN 50130-5
EN 50131
EN 50131-2-2, Grade 2, Class IV
Cerftified by Telefication B.V.
Note:
EN 50131-2-2 / SSF 1014 compliant only
when mounted at or below 3 m.
or scan the QR code.
7 / 40
loading