700 Series Conventional Point Detector
Installation Sheet
EN CS DA DE ES
FI
1
3
EN: Installation Sheet
Description
The 700 Series Conventional Point Detectors are compatible
with with DB702 and DB702U mounting bases.
Table 1: 700 Series Conventional Point Detectors
Model
Detector type
DP721I
Optical Smoke Detector with Remote Indicator Output
DP721R
Optical Smoke Detector with Relay Output
DP721RT
Optical/Heat Multi Detector with Relay Output
DP721T
Optical/Heat Multi Detector with Remote Indicator Output
DT713-5
Heat Detector, 57° C fixed and rate of rise heat detector
DT713-5R
Heat Detector, 57° C fixed and rate of rise heat detector
with relay output
DT713-7
Heat Detector, 70°C fixed and rate of rise heat detector
© 2021 Carrier. All rights reserved.
FR HU
IT
NL NO PL PT RO SV TR
2
4
Installation
Caution:
For general guidelines on system planning, design,
installation, commissioning, use and maintenance, refer to
CEN/TS 54-14 and to local regulations.
To install a detector:
1.
Insert the detector head into the mounting base and rotate
it clockwise until it clicks into place.
The detector may be locked into the mounting base if required.
To do this remove the locking tab on the detector before
installation (Figure 1).
Every 700 Series base features a continuity link between LINE
IN (1) and LINE OUT (2) terminals of the conventional detector
circuit. The base is supplied with the link in closed position.
The link is enabled by default allowing you to check the zone
wiring using only the bases. The link will automatically
disconnect when a detector is inserted, allowing the panel to
generate a fault message when the detector is removed.
1 / 28
P/N 10-4226-501-1C70-09 • ISS 08JUN21
Tabla de contenido
loading

Resumen de contenidos para Aritech 700 Serie

  • Página 8: Es: Hoja De Instalación

    DT713-5R Detector de temperatura, 57° C termovelocimétrico con Erklärung der salida de relé Performance-Nummer DP721I, DP721R 360-4227-0399 DT713-7 Detector de temperatura, 70°C termovelocimétrico DT713-5, DT713-5R, 360-4227-0599 DT713-7 360-4227-0599 DP721RT, DP721T 360-4227-0799 Instalación Jahr der ersten CE- Kennzeichnung Precaución: Consulte la norma CEN/TS 54-14 y las Produktidentifikation Siehe Modelnummer auf dem Produkt- normativas locales para obtener información acerca de las...
  • Página 9: Información Relativa A Las Normativas

    Para limpiar la cámara óptica, siga las instrucciones anteriores Peso para su extraerlo y utilice aire comprimido para quitar el polvo. DP721I 112 g DP721R, DP721RT 115 g Precaución: Tras sustituir o limpiar la cámara óptica, DP721T 109 g DT713-5 84 g compruebe la sensibilidad con la prueba de nivel de DT713-5R...

Este manual también es adecuado para:

Dp721Dp721rDp721rtDp721tDt713-5Dt713-5r ... Mostrar todo

Tabla de contenido