ALARM CODES
7. ALARM CODES
ALARM
CAUTION
EN
E01
E03
8. TROUBLESHOOTING
The system fails to come on (green LED off)
Cause
» No mains voltage at the socket.
» Faulty plug or cable.
» Line fuse blown.
» Faulty on/off switch.
» Faulty electronics.
No output power the system does not weld
Cause
»
» The system has overheated (temperature alarm -
yellow LED on).
» Incorrect earth connection.
» Mains voltage out of range (yellow LED on).
» Faulty contactor.
» Faulty electronics.
Incorrect output power
Cause
» Incorrect selection in the welding process or faulty
selector switch.
» System parameters or functions set incorrectly.
» Faulty potentiometer/encoder for the adjustment
of the welding current.
» Mains voltage out of range.
E02
E20
Solution
» Check and repair the electrical system as needed.
» Use qualified personnel only.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Replace the faulty component.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Contact the nearest service centre to have the system repaired.
Solution
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Wait for the system to cool down without switching it off.
» Earth the system correctly.
» Read the paragraph "Installation ".
» Bring the mains voltage within the power source admissible range.
» Connect the system correctly.
» Read the paragraph "Connections ".
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Contact the nearest service centre to have the system repaired.
Solution
» Select the welding process correctly.
» Reset the system and the welding parameters.
» Replace the faulty component.
» Contact the nearest service centre to have the system repaired.
» Connect the system correctly.
» Read the paragraph "Connections ".