HTW NEO -BP21MDA Manual De Usuario E Instalacion página 42

Bomba de calor para piscinas
Idiomas disponibles
  • ES

Idiomas disponibles

USER AND INSTALLATION MANUAL
6. OPERATING THE UNIT
Error
Meaning
High-pressure
P08
2 protection
P11
DC fan fault
High
temperature
P12
protection of
heating water
outlet
Controller
E01
communication
failure
TP1
exhaust gas
E02
temperature
sensor failure
T3 coil
E03
temperature
sensor failure
T4 ambient
E04
temperature
sensor failure
T5 liquid gas
E05
temperature
sensor
TH return gas
E06
temperature
sensor failure
TW water tank
E07
temperature
sensor failure
T6 inlet water
E08
temperature
sensor failure
T7 outlet water
E09
temperature
sensor failure
Controller and
Drive PCB
E10
Communicate
failure
40
Analysis
High pressure switch 2
cuts
1. The fan is faulty or
stuck.
2. The main control
board is faulty
1. Too low water flow
2. Main PCB damaged
Communication cable
cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Sensor temperature
deviation or cuts
Communication cable
cuts
SWIMMING POOL HEAT PUMP/ SPA NEO
Diagnosis
High pressure switch 2
cuts
1. Check whether the fan
is stuck, or replace
with a new fan.
2. Replace the main
control board
1. Check if water in valve
is closed or no water
in;
2. Check if flow switch is
blocked or damaged;
3. Check if "Y" Shape
filter blocked.
Check communication
cable if cut
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check sensor resistance
value or if sensor cuts
Check communication
cable if cut
Solution
1. Reinject water or change
to a new pump of larger
water flow;
2. Change a new high-
pressure switch;
3. Change a new
filterChange a new EEV.
1. Check if the fan is stuck,
or replace with a new fan.
2. Replace the main control
board.
1. Check the water filter and
water circuit (no block)
2. Replace the PCB
Change connection cable or
re-connect
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change sensor or re-connect
cable
Change connection cable or
re-connect
loading

Este manual también es adecuado para:

Neo htw-bp17mdaNeo tw-bp14mdaNeo htw-bp09mdaNeo htw-bp07mda