SWIMMING POOL HEAT PUMP/ SPA NEO
5.8 SERIAL INSTALLATION DIAGRAM
The filter must be cleaned regularly to ensure that the water in the system is clean and to avoid any
problems related to dirt or clogging of the filter.
5.9 ELECTRICAL CONNECTION
Electrical supply must correspond to that indicated on the appliance.
Connection cables have to be sized according to appliance power and installation requirements. Please
refer to below table:
These data are only indication, you must ask an electrician to determine the exact data for your pool installation.
Use the cable glands and grommets provided inside the heat pump to route cables.
WATER OUT
WATER IN
WATER OUT
CIRCULATION PUMP
WATER IN
VENT
Heat pump
7
9
14
17
21
25
POOL
FILTER
Cable size
3 x 1,5 mm2/AWG 16
3 x 1,5 mm2/AWG 16
3 x 2,5 mm2/AWG 14
3 x 2,5 mm2/AWG 14
3 x 4,0 mm2/AWG 12
3 x 4,0 mm2/AWG 12
USER AND INSTALLATION MANUAL
5. INSTALLATION
33