Druck SENSYCAL DPI800 Manual De Instrucciones página 8

Ocultar thumbs Ver también para SENSYCAL DPI800:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
Table 2: Menu Options - Select Task
Options
Description
(If applicable)
UMM only. An IDOS measurement task.
IDOS
Pressure options only. A leak test.
To set up the way the instrument works.
Additional data: Refer to: Set Up (Table 1).
a. Optional item
Table 3 shows all the one and two function operations that
are available. If you attach a UMM, you can only use the
options that include IDOS.
Table 3: Permitted 1 and 2 Function Operations
Function
P1
(1)
mA
(1)
(2)
a
(1)
(2)
mA(24V)
a
x
(2)
a
x
(2)
(1)
(2)
IDOS
(1)
(2)
P2
a. DPI802/802P only.
1.7 Set up the Settings
When the task is set up (Table 2 & Table 3), use the
Settings menu to adjust the measurement operation.
Display: Task
1
P1 + mA
P1... g
0.000

55mA
0.000
Sk2
Sk2 = Settings
Menu:
4
Settings
Sk2
(Table 4)
If there is additional data for a menu option, select Settings
() to see the values that are set up. If necessary, adjust
the values. Refer to "Edit Functions" on page 4.
Copyright 2003 Baker Hughes Company.
4 | DPI800/802 Instruction Manual–English
∆P...
P2
(Table 2)
IDOS
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
x
(2)
(2)
x
x
x
(2)
Settings selection
2
(If applicable)
P1
mA
Settings
5
6
x:y
mA
123ABC
+04.000
+04.000
=
MENU

+20.000
+20.000
=
OK
Sk1
[]/[ ]
Sk1 = Edit
Table 4: Menu Options - Settings
Options
(If applicable)
... Units
x
3
1.8 Edit Functions
MENU
OK
Example 1) Set up a label for x:y Scaling = %
Settings
x:y
mA
123ABC
+04.000
+04.000
=
+20.000
+20.000
=
Sk1
Sk1 = Edit
Edit
_
-
_ + . % ^ & * / \
q w e r t y u i o p
a s d f g h j k l
z x
c
v b n m
OK
Shift
Figure A3 - item [26]
Description
To select one of the fixed units of measurement
(psi, mbar ...).
Gage sensors or sensors with differential
operation (P1, P2, IDOS). A zero correction that
makes the instrument read zero at local
pressure.
To include maximum, minimum and average
values for the measurement task.
To select and set up a tare value for the
measurement task (a specified value or the
reading on the display).
The instrument subtracts a positive tare value,
and adds a negative tare value.
Additional data: Select Settings ()
To select and set up a scale of values: One local
scale for each measurement task (Maximum: 5).
Additional data (Example 1/2): Select Settings
()
To select and set up the filter values to give a
smoother output for the measurement task:
Band as a % of full scale (FS). The filter
compares each new value with the previous
value. If the new value is outside the band, it is
not filtered.
Low pass filter time constant in seconds.
Increase the value to increase the damping
factor.
Additional data: Select Settings ()
To select and set up the alarm values for the
measurement task (maximum and minimum).
Additional data: Select Settings ()
Leak Test only. To set an applicable period for
the leak test (Hours:Minutes:Seconds).
1
Edit
2
_
1
2 3 4 5 6 7 8 9 0
Q W E R T Y U I O P
 
A S D F G H J K L
+
Z X
C
V B N M

OK Shift
BS
Figure A3 - item
[26]
...
Edit
OK
%_
BS
Edit
3
MENU
Shift
OK
4
5
MENU
OK
+
