5.2.
Correct operation during firing
⇒ Do not place flammable objects near the kiln.
⇒ The kiln may only be used in a well-ventilated room.
⇒ In order to guarantee safe operation, the kiln may be only operated up to an environmental temperature of
+30°C.
⇒ The kiln must be placed in a free-standing position in the room. Make sure that the heat release is not
blocked.
⇒ Do not place any objects on top of or around the kiln.
⇒ Never open the kiln during operation or before it has cooled down completely. High temperatures are
released and might cause physical injury and material damage. The manufacturer of the kiln does not
assume any liability in such cases!
⇒ When firing materials which release hazardous gases and fumes, an exhaust air system must be installed
that directs these into the open air.
⇒ Never use your kiln for firing inflammable materials or food.
5.3.
Air supply & exhaust air
5.3.1.
Air supply handle
General note
Note
You can significantly increase the service life of the heating elements by opening
the air supply and exhaust air up to a temperature of 600 – 700°C.
Description (all KE except KE 35/65 B & KE 65 B eco)
Step
Action required
Rohde Frontloaders are equipped with an air supply opening and
1
handle on the bottom of the kiln.
2
Push the handle in fully to close the exhaust air opening.
3
To open the air supply, pull the handle out completely.
38 / 166 - EN -
Illustration