Commissioning / After initial use / Maintenance
Adjusting the compressed air
Note: this device is designed for an operating
pressure of up to 6.8 bar and a compressor with
the minimum air flow specified in the technical spe-
cifications. When setting the air pressure, remem-
ber the pressure drops by approx. 0.6 bar with a
hose length of 10 m and an inner diameter of
9 mm.
Only use filtered, lubricated and regulated
compressed air.
Initial use
Activate the On / Off switch
the device.
Release the On/ Off switch
device off.
Changing rotation
ATTENTION! The device must come to a
complete standstill before changing the direc-
tion of rotation.
ATTENTION! A machine rotating in an unex-
pected direction can be dangerous. Always
pay attention and use care.
Note: The power drill is designed for clock-
wise/counter-clockwise rotation. Use the
forward/reverse switch
direction of rotation of the power drill.
Set the forward/reverse switch
to switch to clockwise rotation.
Set the forward/reverse switch
to switch to counter-clockwise mode.
After initial use
Once the task has been finished the device must be
disconnect from the compressed air supply
Briefly activate the On / Off switch
device to bleed any residual compressed air.
Now pull back the safety on the connection
coupling of your compressed air hose.
48 GB/MT
110140_par_Druckluft Bohrmaschine PDBM_content_ES_IT_PT.indd 48
All manuals and user guides at all-guides.com
to start using
3
to switch the
3
to change the
4
to position F
4
to position R
4
.
5
on the
3
Now remove the hose from the plug nipple
Careful when putting the device
down. Always put down the device so it does
not rest on the trigger. This could potentially re-
sult in inadvertent activation of the tool, which
in turn could result in hazards.
Maintenance
ATTENTION! All maintenance must be per-
formed by trained individuals. Follow the specified
maintenance instructions to ensure a long life and
proper operation of this quality product.
Disconnect equipment from the compressed air
source when performing maintenance and care.
Check the condition of wear and tear items
and accessories with each maintenance.
Note: Daily cleaning and regular lubrication
are an absolute necessity for smooth operation.
Only use special tool oil with a high viscosity
(thin fluid). Oil for compressed air tools or
SAE10-20 motor oil are suitable.
ATTENTION! Do not use other (especially
high viscosity) lubricants. Malfunctions or per-
manent damage may otherwise occur.
The following lubricating options are
available:
a) via oil-mist generator
To use the oil-mist generator plug the plug
nipple
directly into the equipment and con-
8
nect with your air hose.
b) by hand
Alternatively you can also manually lubricate
your equipment (not recommended).
To do so, remove the screw plug on the oil filler
port.
Apply 3–5 drops of oil to the compressed air
connection before using the compressed air
tool
.
4
If the air tool has not been used for several
days 5–10 drops of oil must be added to the
air connection
.
5
.
8
26.06.15 14:18