Hitachi Air Home 600 Manual De Instrucciones página 14

Ocultar thumbs Ver también para Air Home 600:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
Regular Inspection
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED
SERVICE PERSONNEL EITHER EVERY HALF YEARLY OR
YEARLY. CONTACT YOUR SALES AGENT OR SERVICE
SHOP.
1
2
3
AFTER SALE SERVICE AND
WARRANTY
WHEN ASKING FOR SERVICE, CHECK
THE FOLLOWING POINTS
CONDITION
If the remote controller is
not transmitting a signal.
(Remote controller
display is dim or blank.)
When it does not cool
well
When it does not cool well
When it does not hot well
Is the earth line disconnected or
broken?
Is the mounting frame seriously
affected by rust and is the outdoor
unit tilted or unstable?
Is the plug of power line fi rmly
plugged into the socket?
(Please ensure no loose contact
between them).
CHECK THE
FOLLOWING POINTS
Do the batteries need
replacement?
Is the polarity of the inserted
batteries correct?
Is the fuse all right?
Is the voltage extremely high
or low?
Is the circuit breaker "ON"?
Is the setting of operation
mode different from other
indoor units?
Is the pre-fi lter blocked with
dust?
Does sunlight fall directly on
the outdoor unit?
Is the air fl ow of the outdoor
unit obstructed?
Are the doors or windows
opened, or is there any
source of heat in the room?
Is the set temperature
suitable?
Are the air inlets or air
outlets of indoor and outdoor
units blocked?
Is the fan speed "LOW" or
"SILENT"?
FrostWash Operation
It does not wash when outside
temperature is less than about 1
degrees Celsius or more than 43
degrees Celsius.
It does not wash when the humidity
in the room is about 30% or less or
FrostWash
about 70% or more.
Operation does
When "FrostWash" is done by
not start
operating a remote controller, it does
not wash when the room temperature
is less than about 10 degrees Celsius
or more than about 32 degrees
Celsius.
When 60 minutes after the end of
"FrostWash", "FrostWash" is not
operated for product protection.
It is the sound that the internal
Noise occurred
machine is infl ated and contracted
during FrostWash
by the temperature change and the
operation
fi n of the heat exchanger is frozen
and thawed
Repeat for 1 second on and 1 second
off for 10 seconds
Because "FrostWash" can not work
when operating the "FrostWash" with
remote controller.
(Clean
Function Lamp)
blinks
Repeat for 4 seconds on and 1 second
off for 15 seconds
Because FrostWash has not been done
for a long time.
operate "FrostWash".
Mold Guard Operation
If the air conditioner operation is stopped
after heating operation, Mold Guard will
not operate.
If the air conditioner has operated in
cooling and drying mode, including
auto mode, for less than 10 minutes,
Mold Guard
the Mold Guard operation will not start
operation does
even if the air conditioner is in off mode.
not start
If operation of the air conditioner is stop
by OFF Timer or GoodSleep Timer, the
Mold Guard will not operate.
If ON Timer is set and on time is within
about 2 hours, the Mold-Guard will not
operate.
indoor unit lights up during Mold
During Mold
Guard operation. If Mold Guard
Guard
operation stop at middle point,
FrostWash and Filter sign indicator
will turn off.
– 14 –
The air conditioner is operating
Outside air temperature, room
temperature and room humidity are
not suitable for "FrostWash"
It has not been over 60 minutes since
the end of "FrostWash"
Operate the remote controller to
(Clean Function Lamp) on the
loading

Este manual también es adecuado para:

Rak-vj60phaeRak-vj70phae