Initialization of the Built-in airCloud
Home Module
Reset the internal settings (restore the factory settings)
by remote controller. Please note that the confi guration
will be cleared and pairing procedure will be required
to do again to use the built-in airCloud Home module.
(1) Press Mode key and ON Timer key simultaneously,
pointing the remote controller towards the air
conditioning unit.
(2) Make sure Wi-Fi LED on Indoor Unit fl ashes 4
times repeatedly for about 20 seconds (LED is
turning off between 2 sequences of 20 seconds).
(3) Restart the unit (turn power OFF during 1 minute,
then turn power ON again) and check that the
Wi-Fi LED is blinking 3 times.
If Wi-Fi LED is indeed fl ashing 3 times, pairing
mode is well activated and factory settings have
well been restored.
Status Indicator (LED Indicator may
light up while the air conditioner is
turned off)
Wi-Fi Lamp
Corresponding Status
Pairing time out occurs (after 10 mins.) &
confi gured router not detected.
LED OFF
Air conditioner is not plugged in.
Built-in airCloud Home module and the air
conditioner is not connected.
The connection between the Built-in airCloud
Home module and the router is completed.
LED ON
The operation can be conducted through
smartphone.
LED fl ashes
Waiting to connect to the Wi-Fi router using
3 times
AP mode.
LED fl ashes
Restoring factory setting procedure has started.
4 times
Communication error between air conditioner
LED fl ashes
& Built-in airCloud Home module
5 times
(Error detection time: approx 24 mins.)
LED fl ashes
Router connection error.
with 4 sec ON/
1 sec OFF
LED fl ashes
Cloud connection error. (Error detection time:
with 4 sec ON/
approx 30 mins.)
3 sec OFF
Note:
Please try to power OFF/ON your air conditioner
from mains switch when an error occurs.
Wi-Fi is a trademark or registered trademark of
the "Wi-Fi" Alliance".
Information
Capabilities
Heating Capability
This room air
conditioner
utilizes a heat
pump system
that absorbs
exterior heat
and brings it
into a room
to be heated. As the ambient temperature
gets lower, heating capability will also lower. In
such a situation, the inverter work to increase
compressor rpm to keep the unit's heating
capability from decreasing. If the unit's heating
performance is still unsatisfactory, other heating
appliances should be used to augment this unit's
performance.
The air conditioner is designed to heat an entire
room so that it may take some time before you
feel warm. Timer operation is recommended for
effective preheating ahead of the desired time.
Cooling and Dehumidifying Capabilities
If the heat present in a room exceeds the unit's
cooling capacity (for example, if there are many
people in the room or other heating appliances
are used), the preset room temperature may not
be reached.
Refrigerant Information
For the refrigerant charge information, please refer to
the outdoor unit installation manual or specifi cation
label.
– 11 –
CAUTION
Do not use a stove
or any other high
temperature
devices in proximity
to the indoor unit.
PROHIBITION