Powering up and Startup
5.2 STARTUP
The startup is explained in a very simple way, using the programming features with the existing
parameter groups in the menus STARTUP and BASIC.
5.2.1 STARTUP Menu
5.2.1.1 V/f Control Type (P0202 = 0)
Seq
Indication on the Display / Action
1
Monitoring mode.
Press the key ENTER/MENU to enter 1
level of programming mode.
3
When the STARTUP group is selected
Press the key ENTER/MENU.
5
When the desired value is reached, press
ENTER/MENU to save the modification.
Press the key
7
If necessary, modify the content of "P0402
– Motor Rated Speed".
Press the key
9
To end the Start-up routine, press the Key
BACK/ESC.
To return to the monitoring mode, press the
key BACK/ESC again.
30 | CFW500
CALL NOW 800-985-6929
http://www.automatedpt.com
for the next parameter.
for the next parameter.
Figure 5.2: Sequence of the startup group for V/f control
http://www.automatedpt.com
Seq
Indication on the Display / Action
2
The PARAM group is selected, press
the keys
st
STARTUP group.
4
If necessary, press ENTER/MENU to
modify the content of "P0202 – Control
Type" for P0202 = 0 (V/f).
6
If necessary, modify the content of "P0401
–Motor Rated Current".
Press the key
8
If necessary, modify the content of "P0403
–Motor Rated Frequency".
Press the key
or
until selecting the
for the next parameter.
for the next parameter.