14 progress
Connecting to the electrical supply
Before connecting to the electrical supply,
please make sure:
– The fuse and the domestic electrical in-
stallation must be designed for the max.
load of the appliance (see rating plate).
– The domestic electrical installation must
be equipped with a proper earth connec-
tion in accordance with the regulations in
force.
– The socket or the multi-pole off switch
must be easy to access after the appliance
has been installed.
The appliance is shipped without a mains ca-
ble, as - depending on the type of supply
available - a mains lead with a standard plug
designed for the load specified on the rating
plate is required. Insert the plug into a socket
that satisfies the regulations.
The following types of mains cable are suit-
able, taking the necessary rated cross sec-
tion into account:
H07RN-F, H05RN-F, H05RR-F, H05VVF,
H05V2V2-F (T90), H05BB-F.
If the appliance is connected without a plug,
or if the plug is not accessible, a multipole off
switch (e.g. fuses, circuit breaker) with a min-
imum gap of 3 mm between the contacts
must be installed between the appliance and
mains cable. The switch must not interrupt
the earth wire at any point. The yellow-green
earth wire should be 2-3 cm longer than all
other cables.
The connection cable must always be laid
out so that at no point does it reach 50°C
(over room temperature).
After the connection has been carried out,
the heating elements must be tested by be-
ing operated for about 3 minutes.
Terminal block
The appliance is fitted with an easily-acces-
sible 6-way terminal block, with its links al-
ready set for operation on a 400V supply with
neutral (see illustration).
In the case of a different supply voltage, the
terminal block links must be turned in line
with the schemes shown in the illustration.
The protective conductor is connected to the
terminal.
After connection, secure the cable to the ter-
minal block with strain relief.
1
2
3
Electrical connection to the hob
Important! Observe the installation
instructions for hob, built-in cooker or
control box!
This appliance can be connected to the hob
models specified in the «Technical data» sec-
tion.
The socket for connecting the hob is located
on the cooker housing.
The connecting cables of the heating ele-
ments and the protective conductor cable
are brought out from the built-in hob; these
cables are fitted with plug connections.
Insert the plugs and connecting cables in the
appropriate sockets.
This prevents any possible wrong connec-
tion.
The manufacturer accepts no liability if
the safety measures are not observed.
Installation instructions
For ensuring a trouble free use of the installed
appliance, the unit or the column where the
4
5