Dacor Modernist DOC30M977D Serie Instrucciones De Instalación página 23

Horno combinado de microondas empotrable
Ocultar thumbs Ver también para Modernist DOC30M977D Serie:
Idiomas disponibles

Idiomas disponibles

4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes
do not allow grounding through neutral, New Branch circuit installations (1996 NEC),
mobile homes and recreational vehicles, new construction and in Canada.
A
B
C
D
A. Cable from home power supply
B. Black wires (normally L1)
C. Red wires (normally L2)
D. 4-wire flexible conduit from oven
E. Junction box
F. White wires (normally N-neutral)
G. UL listed wire connectors
H. green wires (normally G-ground)
I. UL listed or CSA approved conduit
connector
NQ9300M_MOD_DOC30M977D_DE68-04479A-03_EN.indd 23
1.
Connect the 2 black wires (B) together
using a UL listed wire connector.
E
2.
Connect the 2 red wires (C) together
F
using a UL listed wire connector.
G
3.
Connect the 2 white wires (F) together
using a UL listed wire connector.
4.
Connect the green (or bare) ground
wire (H) from the oven cable to the
H
green (or bare) ground wire (in the
junction box) using a UL listed wire
I
connector.
5.
Install junction box cover.
English 23
2019-09-20 PM 3:46:38