• Overloaded:
The tool is operated in a manner that causes it to
draw an abnormally high current.
In this situation, release the trigger switch on the tool
and stop the application that caused the tool to
become overloaded. Then pull the trigger switch
again to restart.
If the tool does not start, the battery is overheated.
In this situation, let the battery cool before pulling the
trigger switch again.
• Low battery voltage:
The remaining battery capacity is too low and the
tool will not operate. In this situation, remove and
recharge the battery.
Indicating the remaining battery capacity (Fig. 3)
Only for battery cartridges with the indicator
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for a few seconds.
Indicator lamps
Lighted
Off
015658
NOTE:
• Depending on the conditions of use and the ambient
temperature, the indication may differ slightly from the
actual capacity.
Switch action (Fig. 4)
CAUTION:
• Before inserting the battery cartridge into the tool,
always check to see that the switch trigger actuates
properly and returns to the "OFF" position when
released.
To start the tool, simply pull the switch trigger. Tool speed
is increased by increasing pressure on the switch trigger.
Release the switch trigger to stop.
Remaining
capacity
Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery may
have
malfunctioned.
Lighting up the front lamp (Fig. 5)
CAUTION:
• Do not look in the light or see the source of light
directly.
Pull the switch trigger to light up the lamp. The lamp
keeps on lighting while the switch trigger is being pulled.
The light automatically goes out 10 – 15 seconds after
the switch trigger is released.
NOTE:
• Use a dry cloth to wipe the dirt off the lens of lamp. Be
careful not to scratch the lens of lamp, or it may lower
the illumination.
Reversing switch action (Fig. 6)
This tool has a reversing switch to change the direction of
rotation. Depress the reversing switch lever from the A
side for clockwise rotation or from the B side for counter-
clockwise rotation.
When the reversing switch lever is in the neutral position,
the switch trigger cannot be pulled.
CAUTION:
• Always check the direction of rotation before operation.
• Use the reversing switch only after the tool comes to a
complete stop. Changing the direction of rotation
before the tool stops may damage the tool.
• When not operating the tool, always set the reversing
switch lever to the neutral position.
Characteristics of Cordless Oil-impulse Driver
The Makita Cordless Oil-impulse Driver is a hydraulically
operated impact tool using oil viscosity to produce
impacts. Since oil viscosity changes with the tempera-
ture, be aware of the following three points when operat-
ing the tool.
1.
Avoid using the tool below –5 degrees of tempera-
ture. When the tool temperature goes down below
the degrees, this may cause damage to the motor of
tool due to poor impulse.
2.
When the tool becomes too hot, it may take longer to
set screws.
3.
The tool can overheat, causing a failure or hand
burn if you operate it continuously for long hours. Let
the tool cool off for more than 30 minutes before
changing batteries during a long, continuous job.
ASSEMBLY
CAUTION:
• Always be sure that the tool is switched off and the bat-
tery cartridge is removed before carrying out any work
on the tool.
Installing or removing driver bit or socket bit
Use only bits that has inserting portion shown in the fig-
ure. (Fig. 7)
For tool with shallow bit hole
Use only these type of bit. Follow the
A = 12 mm
procedure (1).
B = 9 mm
(Note) Bit-piece is not necessary.