WIKA NS 160 Manual De Instrucciones página 11

Ocultar thumbs Ver también para NS 160:
Idiomas disponibles

Idiomas disponibles

2. Safety
1. Design temperatures
Permissible ambient temperature
-20 ... +60 °C
-40 ... +60 °C
only instruments with silicone oil filling
For instruments with a permissible ambient temperature deviating from
For instruments with a permissible ambient temperature deviating from
-20 ... +60 °C, this is indicated on the dial.
-20 ... +60 °C, this is indicated on the dial.
Permissible medium temperature (instrument)
-20 ... +100 °C
-20 ... +150 °C
-20 ... +200 °C
The permissible medium temperature does not only depend on the instrument
design, but also on the ignition temperature of the surrounding gases, vapours or
dusts. Both aspects have to be taken into account. For instruments with case filling
(marking with additional label "liquid filling"), the maximum permissible medium
temperature is ≤ 100 °C.
The limits of the permissible temperature ranges of an "instrument hook-up"
mounting arrangement are determined, in each case, by the component with the
greatest restriction.
2. Maximum surface temperature
The surface temperature of the instruments mainly depends on the medium
temperature of the application. The instrument itself does not contain any heat
sources. For determining the maximum surface temperature, besides the medium
temperature also other influences such as the ambient temperature and, if appli-
cable, the solar irradiation must be taken into account. For prevention, consider
the maximum medium temperature as maximum surface temperature, if it is not
possible to determine the real surface temperature even in the case of expected
malfunctions.
WIKA operating instructions pressure gauge model 5 per ATEX
All manuals and user guides at all-guidesbox.com
-40 ... +100 °C
EN
11
loading

Este manual también es adecuado para:

Ns 1005