Replacing The Deodorizer Cartridge; Cleaning The Mesh Filter - brondell S1200-EW Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE (cont.)

REPLACING THE DEODORIZER CARTRIDGE

Replacement Deodorizer Cartridges are available for purchase at brondell.com.
1. Locate the Deodorizer Compartment at the rear of the Swash. It is on the right-hand side, if you
are facing the toilet.
2. Pull the tab that extends from the compartment until the compartment is completely removed
from the Swash.
3. Pull the old Deodorizer Cartridge out from the compartment and replace it with the new one.
4. Push the Deodorizer Compartment back into the back of the Swash.

CLEANING THE MESH FILTER

Cleaning intervals will differ depending on use and water
quality. It is recommended to check the filter at least once a
year.
1. Turn off the water supply and hold the toilet's flush lever
down until all of the water has drained from the tank.
2. Unplug the Swash, remove the seat from the toilet using
the Quick Release button on the left side of the unit (see
diagram on page 9), and disconnect the bidet hose. You
may want to use a bucket to catch any dripping water
from the bidet hose.
3. Remove the Mesh Filter from the water inlet with a pair of
tweezers or needle-nosed pliers.
3. Clean the filter with a toothbrush while running under tap
water to effectively remove any foreign substances or
build-up.
4. Replace the Mesh Filter and carefully check that it is
installed correctly. If improperly installed, it could result in
the product leaking water.
5. Reconnect the bidet hose and place the seat back on the
toilet. Plug the cord back in, and turn the water supply
back on.
30
Step 3
Tabla de contenido
loading

Este manual también es adecuado para:

S1200-rwS1400-ewS1400-rwS1400-ebS1400-rb

Tabla de contenido