9. Temperature Test Points
Youcanuseamaximumoftwotemperature sensors for meas-
uring the gas temperature in the meter housing for the meter
sizes listed in the table below (quantometers cannot be fitted
withthermowellsinthemeterhousing;onTRZ2thermowellsare
optionaluptonominaldiameterDN150):
Max.
TRZ2
sensor
DN
dia.
50
80
80/100
6 mm
100
100/150
150
GGG=Spheroidalgraphitecastiron;ST=Steel
EBL=Roundedinstallationlengthofthethermowellinmm
Notethattemperaturemeasurementonmeasurementsystemsintheopenairmaybeinfluenced
bytheambienttemperature.Forthisreason,themetering elements outside the pipe should
be adequately insulatedagainstambienttemperatureinfluences. In order to achieve optimum
thermalconduction,youshouldalsoalwaysfillthethermowell(s)withaheat-conductivefluidor
paste.
If no temperature test points in the meter housing are scheduled, the temperature must be
measured in the pipe downstream of the turbine gas meteratadistanceofupto3xDN,but
max.600mmaway.
©ElsterGmbH·Allrightsreserved·Subjecttotechnicalmodification
Housing
PN10/16
material
EBL
GGG
—
ST
—
GGG
45 (2x)
ST
45 (2x)
GGG
58 (2x)
ST
58 (2x)
GGG
50 (2x)
ST
50 (2x)
GGG
67 (2x)
ST
67 (2x)
GGG
50 (2x)
ST
50 (2x)
PN25/40
Class
150
—
—
—
—
—
45 (2x)
45 (1x)
45 (2x)
—
58 (2x)
58 (1x)
58 (2x)
—
50 (2x)
50 (1x)
50 (2x)
—
67 (2x)
67 (2x)
67 (2x)
—
50 (2x)
50 (2x)
50 (2x)
Elster-Instromet
Class
Class
300
600
—
—
—
—
—
—
45 (1x)
45 (1x)
—
—
58 (1x)
58 (1x)
—
—
50 (1x)
50 (1x)
—
67 (2x)
67 (2x)
67 (2x)
—
—
50 (2x)
50 (2x)
11