A
B
5
30°
1
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, the opening must be
sized per local codes.
2
Wall
1
3
2
CONNECT TO DRYER
5
VERTICAL EXHAUST INSTALLATION
1
No Screen or Cap
2
Roof
3
Wall
4
2 in. (5 cm) Minimum or Clearance Per Local
Codes
5
NOTE: Where the exhaust duct pierces a
combustible wall or ceiling, an opening must
be sized as shown or per local codes.
Figure 41
801539
C
D
E
F
G
HORIZONTAL EXHAUST INSTALLATION
4
H319I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
H
I
J
K
FLOW
EXHAUST AIR FLOW
MAXIMUM LENGTH OF DUCT
30 feet (9.1 m)
3
2 in. (5 cm) Minimum or Clearance per Local
Codes
4
No Screen or Cap
5
Clean Out Cover – Inspect Monthly
Figure 40
To reduce the risk of fire and the
accumulation of combustion gases, DO NOT
exhaust dryer air into a window well, gas
vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
Duct
Station
A
B
C
D
E
F
G
H
I
J
K
2
3
AIR
EXHAUST
OUTLET
WARNING
Minimum Diameter of
Collector Duct
4 inches (10.2 cm)
8 inches (20.3 cm)
9 inches (22.9 cm)
10 inches (25.4 cm)
11 inches (27.9 cm)
12 inches (30.5 cm)
13 inches (32.6 cm)
14 inches (35.6 cm)
15 inches (38.1 cm)
15 inches (38.1 cm)
16 inches (40.6 cm)
Installation
4
H318I
W045
47