Installation
GAS CONNECTION
The configuration of the appliance supply is indicated by a marking on the information plate affixed to the back
of the appliance.
To change the gas configuration of your appliance, refer to the "Adjustment" section (page 19).
- The plancha must be connected via a coupling located at the back of the appliance using a hose complying with
the NF D 36121 standard for natural gas and the NF D 36125 standard for gases of the 3
- Check the sealing of the coupling using soapy water.
- Never test leak-tightness using a flame.
Connection for using your appliance in category I3+
BUTANE
For Butane G30 gas, use an NF 28 mbar safety pressure regulator
- NFD36-125 metal hose / length: 1 m
- NFD36-112 hose / length: 1 m
PROPANE
For Propane G31 gas, use an NF 37 mbar safety pressure regulator
- Nipple end piece forbidden
- NFD36-125 metal hose / length: 1 m
- NFD36-112 hose / length: 1 m
Connection for using your appliance in category I2E+
NATURAL GAS
For Natural gas G20 and G25
- The butane type nipple end piece is forbidden
- NFD36-121 metallic hose
Type of gas and
Country
pressure
BE, CH, ES,
G30/G31
FR,
28-30/37 mbar
GB, GR, IT,
PT, IE
G30/G31
DE
50 mbar
G20/G25
BE, FR
20/25 mbar
CH, ES,
G20
GB, IT, PT,
20 mbar
IE, GR
G20
DE
20 mbar
Opening of
Injector
the air
By-pass marks
marking
collars
4 mm
80
4 mm
72
Adjustment of
1 mm
120
loosened by one
Adjustment of
1 mm
120
loosened by one
Adjustment of
1 mm
120
loosened by one
- 15 -
Rated
flow
consumption
G30 : 327 g/h
55 (tight)
4500 W
G31 : 321 g/h
G30 : 327 g/h
50 (tight)
4500 W
G31 : 321 g/h
the by-pass:
G20 : 476 g/h
4500 W
G25 : 553 g/h
turn
the by-pass:
4500 W
turn
the by-pass:
4500 W
turn
rd
Butane/Propane family.
Rated
Reduced
flow
2000 W
2000 W
2000 W
476 g/h
2000 W
476 g/h
2000 W