5
MAINTENANCE
In case of failure, check the fuse and the wiring (Fig. 2).
5.1
Troubleshooting
FAULT
The LEDs turn on but
are unable to control the
relevant valves
All LEDs are OFF and
the valves do not work
Switches are set to OFF
(lever down) but valves
are open
6
TECHNICAL DATA
Description
Power supply
Max. switching current per each output (section)
Max. switching current per each output (Adjustable
actuators / Guard actuators)
Working temperature
Stocking temperature
Output protection through resettable fuse
Dimensions
Weight
7
DISPOSAL AT THE END OF SERVICE
Dispose of the system in compliance with the established legislation in the country of use.
CAUSE
Disconnected connectors
Internal protection is active
Burnt fuse inside electric
circuit (Fig. 2)
Power supply failure
Reversed power cable
• Connect the connectors.
• Cut-off the supply and wait for at least 20 seconds
before switching the control box on.
If the problem persists, please contact the nearest
Assistance Centre.
• Replace the fuse. If the problem persists, please
contact the nearest Assistance Centre.
• Check power supply.
• Check power cable connection.
4669 series control box
12 Vdc (Vmin 9 / Vmax 16)
3 A
5 A
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
present
80 x 115 x 93 mm (harness excluded)
600 ÷ 1396 g (according to the type)
11
REMEDY
Tab. 2