2.3 Control Functions
SMART RUN Acelerador
When the Smart Run switch is in
the "ON" position the throttle
ON
controls the engine load. The
results are better fuel consump-
tion and less noise. When the
S
switch is in the "OFF" position the
engine
regardless of the electrical load.
OFF
Note:
The Throttle must be "OFF" when using electrical
devices that require a large starting current, such as
a compressor, pump, or refrigerator.
LED Indicators
The LED Indicators assist in communicating status
and functions of the unit .
Output Indicator (Green)
The Output Indicator comes on when the engine
starts and produces power.
Overload Alarm (Red)
The Overload Alarm comes on
when a connected device requires
more power than the generator is
able to produce, The Output Indi-
cator (Green) will go off and the
Overload Alarm (Red) will stay on,
but the engine will continue to run.
Low Oil Alert (Red)
When the engine oil falls below the required level
the Low Oil Alert will come on .and the engine will
stop automatically. The engine will not restart until
oil is added to the unit to bring it up to the appro-
priate level.
www.ducsonpower.com
runs
at
4,500
rpm
To Reset the Generator
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric
devices within the rated output.
3. Use in proper ventilated areas. Maintain at least
3ft of clearance on all sides for adequate cooling.
4. After checking, restart the engine. ( refer to part
3.4 in this manual for how to start) .
Note:
The Overload Alarm may come on for a few
seconds when first using electrical devices that
require a large starting current, such as a com-
pressor, pump, or refrigerator . This is normal and
not a malfunction.
Note:
When starting the unit, if the Low Oil Alarm light
flickers and the engine will not start, you will need
to add engine oil before attempting to restart the
engine.
Note:
Generator should only be operated on a level
surface. DO NOT operate the generator on loose
ground or obvious inclines. The low oil shutdown
feature may be prematurely activated in these
cases causing the engine to not start.
12V SA DC
The 12V BA DC Output is for provided for battery
charging. Follow instructions in the owner's manual
for the battery for charging procedures .
SA DC Circuit Breaker
The BA DC Circuit Breaker
turns off automatically if the
current exceeds BA. If the
circuit breaker turns "OFF" you
will need to push it "in" to turn
it "ON" again.