SICK GRTE18 Instrucciones De Operación página 25

Ocultar thumbs Ver también para GRTE18:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
6
Disassembly and disposal
7
Maintenance
8016953.1HT2/2022-11-11 | SICK
Subject to change without notice
LED/fault pattern
Yellow LED flashes
Yellow LED lights up, no object
in the path of the beam
Object is in the path of the
beam, yellow LED does not
light up
Object is in the path of the
beam, yellow LED does not
light up
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
OPERATING INSTRUCTION
Cause
Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
Excessive background remis‐
sion
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Remission capability of the
object is insufficient
O P E R A T I N G I N S T R U C T I O N | GRTE18
Measures
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object. / Clean the optical sur‐
faces . / Readjust the sensi‐
tivity (potentiometer) / Check
sensing range and adjust
if necessary,
see "Check
the application conditions",
page
19.
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Increase the sensing range,
take note of the distance
between the sensor and the
background
Increase the sensing range,
take note of the distance
between the sensor and the
background
25
en
loading