Setting
8016953.1HT2/2022-11-11 | SICK
Subject to change without notice
Figure 4: Alignment
Figure: F
Sensor with potentiometer:
The sensitivity (sensing range) is adjusted with the potentiometer (type: 270°). Clock‐
wise rotation: sensitivity (sensing range) increased; counterclockwise rotation: sensitiv‐
ity (sensing range) reduced. We recommend placing the sensing range in the object,
e.g., see Graphic F. Once the sensitivity has been adjusted, the object is removed from
the path of the beam. The switching output changes (see Graphic C).
The sensor is adjusted and ready for operation. Refer to Graphics C and G to check the
function. If the switching output fails to behave in accordance with Graphic C, check the
application conditions. See section Error analysis.