SOMFY TLW25 WT Instrucciones página 20

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
EN
2.1.3. Motor and shaft locking
1) Using the relevant tool, pinch headrail edges to
block motor translation.
2) To lock the shaft, place stop rings against the CTS,
and screw them.
Attention
If needed, install the "TL25 WT switching sensor"
2.2. WIRING
2.2.1. Rotation according to power supply
Reverse the polarity of cables a and b to change the
direction of rotation.
a
Brown cable
+ or -
b
White cable
+ or -
c
Green cable
data
Attention
Secure the cables to prevent any contact with moving parts.
2.3. COMMISSIONING
2.3.1. Setting the up end limit position without TL 25 WT Setting tool.
The motorisation is delivered in its down end limit position in "high speed" factory mode. To exit the
"high speed" factory mode, five runs must be started before entering in user mode.
Press the Up button to raise the motorised product to its up end limit position with the
"TL25 WT switching sensor" or until the torque detection.
Press the Down button to lower the motorised product to its down end limit position,
Press the Up button again to raise the motorised product to its up end limit position with
the "TL25 WT switching sensor" or until the torque detection.
- The motorised product will be ready to operate in user mode, after repeating the last 2
movements once (Down, Up).
If a problem occurs during the setting, go to the chapter 2.4. Tips and advices on operation.
After 5, 20 and every 50 cycles, the motorisation will automatically readjust the end position to user
settings.
2.3.2. Setting the end limits position with the TL 25 WT Setting tool
Refer to the TL 25 WT Setting tool instructions to set the end limits.
20
24 V DC
©
Copyright
2020 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
1)
2)
a
a b
c
b
c
a
b
c
TLW25 WT
TL25 WT
switching
sensor
+
-
-
+
loading