PRECAUTIONS
 Before connecting the unit ensure that the power
supply is 230 V, 50/60 Hz and earthed. It should also
be protected by a thermal magnetic cut-out. Consult
your installer concerning these matters.
 Do not allow children or unskilled personnel to
handle the unit.
 Use long gauntlets and muffle tongs whenever you
put muffles into the tank or take them out.
 Open the cover carefully: steam pouring out from the
tank could cause burns.
 Always keep the unit's cover closed while
polymerisation programs are running.
TECHNICAL DATA
Height x width x depth:
Tank dimensions:
Weight:
Power supply:
Consumption:
Nº muffles with flange:
Ref. 080405
420 x 270 x 480 mm
335 x 180 x 350 mm
15 kg
230 V, 50/60 Hz
1750 W
9
 Never place more than 9 muffles on the polymerising
tray.
 Always keep at least 20 cm of water in the bottom of
the tank, as the heating elements may be damaged if
the level is lower.
 Always leave a gap of at least 15 cm between the
unit's ventilation grille and the nearest wall or other
object.
 Before plugging in the unit, fill the tank with water to
10 cm below the cover.
 TALLERES MESTRAITUA, S.L. recommends
polymerising at around 95 ºC. At higher temperatures
too much steam may be generated.
Ref. 080407
510 x 420 x 500 mm
350 x 320 x 400 mm
20 kg
230 V, 50/60 Hz
3000 W
18