ELECTRICAL AND CONTROL SETTINGS
Input - Setting before shipment
Mark
Description
I1
Input 1
I2
Input 2
I3
Input 3
I4
Input 4
I5
Input 5
I6
Input 6
I7
Input 7
I8
Input 8
I9
Input 9
I10
Input 10
I11
Input 11
!
C A U T I O N
Functions i - 05(Forced Heating/Cooling) /Functions i - 10(Forced heating)/Functions i - 11(Forced cooling) cannot be used at the same time.
Default settings
i - 08
(Demand ON/OFF 1)
i - 13
(Cycle 1 and 2 ECO
mode)
i - 00
(No function)
i - 04
(Solar in)
i - 02
(Smart Act.)
i - 06
(DHW Boost)
i - 07
(Power meter 1)
i - 12
(Power meter 2)
i - 09
(Demand ON/OFF 2)
i - 00
(No function)
i - 00
(No function)
Available input codes
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
i - 00~17
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
i - 00~17
(Except i - 07/12)
28
Terminals
Specification
I1, L1
Closed/Open
220-240V ~ 50/60Hz
on TB3
I2, +12V
Closed/Open
on TB4
12V DC
I3, L3
Closed/Open
220-240V ~ 50/60Hz
on TB3
I4, L3
Closed/Open
220-240V ~ 50/60Hz
on TB3
I5, +12V
Closed/Open
12V DC
on TB4
I6, L3
Closed/Open
220-240V ~ 50/60Hz
on TB3
I7, COM
Closed/Open
12V DC
on TB4
I8, COM
Closed/Open
12V DC
on TB4
I9, +12V
Closed/Open
12V DC
on TB4
I10, +12V
Closed/Open
12V DC
on TB4
I11, +12V
Closed/Open
12V DC
on TB4